Geophysical Investigation of Groundwater Potential in Yobe State University, Damaturu

In order to meet the growing demand for potable water in Yobe State University Damaturu and its environs, due to rapid increase in both students and staff population as well as economic activities within the area, this study investigated the groundwater potential of Yobe State University Damaturu. Vertical electrical sounding method, using Schlumberger configuration was adopted for the study. Five (5) geoelectrical layers were delineated from the study area and these layers were the topsoil which is a mixture of clay and sand, clay, sand, silty clay and sand. The third and the fifth layers were the aquifer systems in the study area. The parameters of the first aquifer were used to evaluate the groundwater potential in the study area. The evaluated parameters of the aquifer were the aquifer thickness, transverse resistance, transmissivity and porosity. The magnitude of the aquifer parameters showed that the study area has good groundwater potential. The aquifer in the study area has an average thickness of 36.3 m and an average porosity of 29.5%. The aquifer transmissivity ranged from 81.8 to 150.6 m2/day indicating good groundwater yield in the area. Based on the findings of this study, it is recommended that boreholes for groundwater abstraction in the study area should be drilled within the second aquifer.

Authors

Institutions

Publication Details

Journal
Nigerian Journal of Physics
Published
2024-12-31
DOI
https://doi.org/10.62292/njp.v33i4.2024.316
Citations
1
Primary Topic
Geophysical and Geoelectrical Methods
Type
article
Field-Weighted Citation Impact
0.53
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Geophysical Investigation of Groundwater Potential in Yobe State University, Damaturu

S. Muhammad, Livinus Emeka Agada
1 citations
Nigerian Journal of Physics
Geophysical and Geoelectrical Methods
0.53
article

Geophysical Investigation of Groundwater Potential in Yobe State University, Damaturu

S. Muhammad, Livinus Emeka Agada
article en
1 citations

Abstract

In order to meet the growing demand for potable water in Yobe State University Damaturu and its environs, due to rapid increase in both students and staff population as well as economic activities within the area, this study investigated the groundwater potential of Yobe State University Damaturu. Vertical electrical sounding method, using Schlumberger configuration was adopted for the study. Five (5) geoelectrical layers were delineated from the study area and these layers were the topsoil which is a mixture of clay and sand, clay, sand, silty clay and sand. The third and the fifth layers were the aquifer systems in the study area. The parameters of the first aquifer were used to evaluate the groundwater potential in the study area. The evaluated parameters of the aquifer were the aquifer thickness, transverse resistance, transmissivity and porosity. The magnitude of the aquifer parameters showed that the study area has good groundwater potential. The aquifer in the study area has an average thickness of 36.3 m and an average porosity of 29.5%. The aquifer transmissivity ranged from 81.8 to 150.6 m2/day indicating good groundwater yield in the area. Based on the findings of this study, it is recommended that boreholes for groundwater abstraction in the study area should be drilled within the second aquifer.

Nigerian Journal of PhysicsVol. 33(4)
Yobe State University (NG)
Openalex Percentile: Top 31%
Geophysical and Geoelectrical Methods
0.53
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.