Improving X-Ray Assessment of Internal Defects Using Filters for Digital Image Processing

Non-destructive testing (NDT) is an essential solution for assessing the integrity of industrial parts without compromising their utility.In this study, the use of X-ray radiographic technique for the evaluation of internal defects in lightweight alloys was investigated, with emphasis on the application of image processing filters.In particular, the performance of the Flash!Filter, a tool integrated into the Rhythm Review software designed to reduce noise and improve contrast was implicated.The study focused on AlSi12(Cu) alloy die-casting parts with wall thicknesses between 3.5 and 13.0 mm.The results showed that the use of the Flash!Filter allows more accurate detection of porosity and cold fill defects, ensuring correct classification according to ASTM E-505.The images processed with this filter showed a significant reduction in background noise and an increase in contrast compared to the raw images, contributing to a more detailed assessment of discontinuities.In addition, the application of the Laplacian filter highlighted the boundaries of the defects by analyzing sudden density changes.

Authors

Institutions

Publication Details

Journal
RECENT - REzultatele CErcetărilor Noastre Tehnice
Published
2024-12-31
DOI
https://doi.org/10.31926/recent.2024.74.234
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improving X-Ray Assessment of Internal Defects Using Filters for Digital Image Processing

Iuliana Lichioiu
RECENT - REzultatele CErcetărilor Noastre Tehnice
Advanced X-ray and CT Imaging
article

Improving X-Ray Assessment of Internal Defects Using Filters for Digital Image Processing

Iuliana Lichioiu
article en

Abstract

Non-destructive testing (NDT) is an essential solution for assessing the integrity of industrial parts without compromising their utility.In this study, the use of X-ray radiographic technique for the evaluation of internal defects in lightweight alloys was investigated, with emphasis on the application of image processing filters.In particular, the performance of the Flash!Filter, a tool integrated into the Rhythm Review software designed to reduce noise and improve contrast was implicated.The study focused on AlSi12(Cu) alloy die-casting parts with wall thicknesses between 3.5 and 13.0 mm.The results showed that the use of the Flash!Filter allows more accurate detection of porosity and cold fill defects, ensuring correct classification according to ASTM E-505.The images processed with this filter showed a significant reduction in background noise and an increase in contrast compared to the raw images, contributing to a more detailed assessment of discontinuities.In addition, the application of the Laplacian filter highlighted the boundaries of the defects by analyzing sudden density changes.

RECENT - REzultatele CErcetărilor Noastre TehniceVol. 25(3)
Transylvania University of Brașov (RO)
Openalex Percentile: Top 76%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Improving X-Ray Assessment of Internal Defects Using Filters for Digital Image Processing — Iuliana Lichioiu · RECENT - REzultatele CErcetărilor Noastre Tehnice (2024) | TGRS Research Map | TGRS