Modification of P&O Method on MPPT with PI Controller to Reduce Power Oscillation during Steady-State Condition

This paper describes an improvement of the Perturb and Observe (P&O) method for maximum power-point tracking (MPPT) on a photovoltaic (PV) cell generating system. The improvement is achieved using a reference voltage () value to respond to perturbation and calculates the power change based on the response. The magnitude of is determined using the reference voltage change . A large will result in a faster tracking but increasing oscillations during steady-state conditions, while a small will reduce oscillations but slowing down the MPPT response. An adaptive value is required to reduce the oscillations which have potential to degrade the efficiency of the PV cell output. A proportional-integral (PI) controller is explored in this paper in determining the most appropriate value. The results showed that oscillations around the MPP point could be reduced by 99%.

Authors

Institutions

Publication Details

Journal
Jurnal EECCIS (Electrics Electronics Communications Controls Informatics Systems)
Published
2024-12-23
DOI
https://doi.org/10.21776/jeeccis.v18i3.1749
Citations
1
Primary Topic
Advanced DC-DC Converters
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Modification of P&O Method on MPPT with PI Controller to Reduce Power Oscillation during Steady-State Condition

Rini Nur Hasanah, Nisrina Rania Habibah, Zainul Abidin
1 citations
Jurnal EECCIS (Electrics Electronics Communications Controls Informatics Systems)
Advanced DC-DC Converters
0.21
article

Modification of P&O Method on MPPT with PI Controller to Reduce Power Oscillation during Steady-State Condition

Rini Nur Hasanah, Nisrina Rania Habibah, Zainul Abidin
article en
1 citations

Abstract

This paper describes an improvement of the Perturb and Observe (P&O) method for maximum power-point tracking (MPPT) on a photovoltaic (PV) cell generating system. The improvement is achieved using a reference voltage () value to respond to perturbation and calculates the power change based on the response. The magnitude of is determined using the reference voltage change . A large will result in a faster tracking but increasing oscillations during steady-state conditions, while a small will reduce oscillations but slowing down the MPPT response. An adaptive value is required to reduce the oscillations which have potential to degrade the efficiency of the PV cell output. A proportional-integral (PI) controller is explored in this paper in determining the most appropriate value. The results showed that oscillations around the MPP point could be reduced by 99%.

Jurnal EECCIS (Electrics Electronics Communications Controls Informatics Systems)Vol. 18(3)
University of Brawijaya (ID)
Openalex Percentile: Top 44%
Advanced DC-DC Converters
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Modification of P&O Method on MPPT with PI Controller to Reduce Power Oscillation during Steady-State Condition — Rini Nur Hasanah, Nisrina Rania Habibah, et al. · Jurnal EECCIS (Electrics Electronics Communications Controls Informatics Systems) (2024) | TGRS Research Map | TGRS