Design Analysis of Floating Solar Plant Development in Lake Toba: Study on Engineering, Economic and Environmental Aspects

High level of solar radiation throughout the year makes solar photovoltaic systems (PV) as one of the options for clean energy sources in Indonesia. Indonesia possesses significant potential for utilizing floating solar plants, given its 3,091 water resources. Lake Toba, situated in the North Sumatra province, stands as Indonesia's largest lake, covering an expansive area of 1,145 km2. With solar irradiation levels reaching 1757.1 <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\text{kWh}/\mathrm{m}2/\text{yr}$</tex>, the lake presents promising potential as a suitable location for floating solar plant installations. The study focused on the technical design of floating solar power plant, covering electrical components and civil structures like floaters, anchors, and moorings. Two scenarios were analyzed to determine plant capacity: maximum water surface area and peak load data of North Sumatra. Inverter capacity was restricted by a ratio of 1.15 to 1.25. Graphical simulations using Matlab software were conducted to assess PV module generation characteristics at various solar radiation levels. Economic analysis included Cost of Energy, Net Present Value, Profitability Index, and Payback Period over a 30-year project lifetime. Environmental analysis addressed GHG emissions reduction assuming a 1% yearly power depreciation. This study outlines the technical design for the Lake Toba floating solar plant with a capacity of 583 MWp covering 3,57 km2 water surface. The plant uses 988,080 PV modules 590 Wp and 48 inverters 10,000 <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\text{kW}$</tex>, mounted on HDPE floaters with a taut mooring system. Estimated energy production stands at 854 <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\text{GWh}/\text{year}$</tex>. Economic analysis reveals a positive NPV of Rp 5.8 trillion, PI exceeding 1 at 1.774, and a Payback Period of 10 years and 2 months, demonstrating the feasibility of constructing the 583 MW Lake Toba Floating Solar Plant. Environmental analysis indicates a reduction in GHG emissions on Sumatra Island by 18.68 kilotons of CO2 over the project's lifetime.

Authors

Institutions

Publication Details

Published
2024-10-16
DOI
https://doi.org/10.1109/eeccis62037.2024.10840162
Citations
1
Primary Topic
Water-Energy-Food Nexus Studies
Type
article
Field-Weighted Citation Impact
0.20
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design Analysis of Floating Solar Plant Development in Lake Toba: Study on Engineering, Economic and Environmental Aspects

Wijono, Unggul Wibawa, William Sutan Nainggolan
1 citations
Water-Energy-Food Nexus Studies
0.20
article

Design Analysis of Floating Solar Plant Development in Lake Toba: Study on Engineering, Economic and Environmental Aspects

Wijono, Unggul Wibawa, William Sutan Nainggolan
article en
1 citations

Abstract

High level of solar radiation throughout the year makes solar photovoltaic systems (PV) as one of the options for clean energy sources in Indonesia. Indonesia possesses significant potential for utilizing floating solar plants, given its 3,091 water resources. Lake Toba, situated in the North Sumatra province, stands as Indonesia's largest lake, covering an expansive area of 1,145 km2. With solar irradiation levels reaching 1757.1 <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\text{kWh}/\mathrm{m}2/\text{yr}$</tex>, the lake presents promising potential as a suitable location for floating solar plant installations. The study focused on the technical design of floating solar power plant, covering electrical components and civil structures like floaters, anchors, and moorings. Two scenarios were analyzed to determine plant capacity: maximum water surface area and peak load data of North Sumatra. Inverter capacity was restricted by a ratio of 1.15 to 1.25. Graphical simulations using Matlab software were conducted to assess PV module generation characteristics at various solar radiation levels. Economic analysis included Cost of Energy, Net Present Value, Profitability Index, and Payback Period over a 30-year project lifetime. Environmental analysis addressed GHG emissions reduction assuming a 1% yearly power depreciation. This study outlines the technical design for the Lake Toba floating solar plant with a capacity of 583 MWp covering 3,57 km2 water surface. The plant uses 988,080 PV modules 590 Wp and 48 inverters 10,000 <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\text{kW}$</tex>, mounted on HDPE floaters with a taut mooring system. Estimated energy production stands at 854 <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\text{GWh}/\text{year}$</tex>. Economic analysis reveals a positive NPV of Rp 5.8 trillion, PI exceeding 1 at 1.774, and a Payback Period of 10 years and 2 months, demonstrating the feasibility of constructing the 583 MW Lake Toba Floating Solar Plant. Environmental analysis indicates a reduction in GHG emissions on Sumatra Island by 18.68 kilotons of CO2 over the project's lifetime.

University of Brawijaya (ID)
Responsible consumption and production
Openalex Percentile: Top 42%
Water-Energy-Food Nexus Studies
0.20
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.