Wave Height Monitoring and Security System on Oscillating Water Column Using ESP32 Microcontroller

This research aims to develop a wave height monitoring and security system for an oscillating water column (OWC) system using the ESP32 microcontroller. The system is capable of collecting real-time wave height data with high accuracy through ultrasonic sensors and is equipped with an automatic security mechanism to ensure the safe operation of the OWC. Testing results show an average sensor error rate of 3% inside the column, 1% outside the column, and an average delay time of 3.3 seconds to open the gate and 1 second to close it. The monitoring device has an error rate below 5%, indicating sufficient accuracy in handling wave fluctuations, and the security mechanism has proven reliable. This research contributes to improved operational sustainability, reduced risk of damage from excessive waves, and optimized renewable energy production from the OWC system.

Authors

Institutions

Publication Details

Published
2024-10-16
DOI
https://doi.org/10.1109/eeccis62037.2024.10840039
Primary Topic
Engineering and Technology Innovations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Wave Height Monitoring and Security System on Oscillating Water Column Using ESP32 Microcontroller

Isra’ Nuur Darmawan, Kholistianingsih, Banyumas Dzanzar Panza Bakti
Engineering and Technology Innovations
article

Wave Height Monitoring and Security System on Oscillating Water Column Using ESP32 Microcontroller

Isra’ Nuur Darmawan, Kholistianingsih, Banyumas Dzanzar Panza Bakti
article en

Abstract

This research aims to develop a wave height monitoring and security system for an oscillating water column (OWC) system using the ESP32 microcontroller. The system is capable of collecting real-time wave height data with high accuracy through ultrasonic sensors and is equipped with an automatic security mechanism to ensure the safe operation of the OWC. Testing results show an average sensor error rate of 3% inside the column, 1% outside the column, and an average delay time of 3.3 seconds to open the gate and 1 second to close it. The monitoring device has an error rate below 5%, indicating sufficient accuracy in handling wave fluctuations, and the security mechanism has proven reliable. This research contributes to improved operational sustainability, reduced risk of damage from excessive waves, and optimized renewable energy production from the OWC system.

Universitas Wijayakusuma Purwokerto (ID)
Clean water and sanitation
Openalex Percentile: Top 76%
Engineering and Technology Innovations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.