Development of Smart Mask System Integrated with Alert Detection and Vital-sign Measurement

This research focuses on enhancing worker safety in environments with high levels of TVOC gases, such as toluene, a neurotoxin. Traditional cartridge replacement methods, based on fixed intervals, lack precision and pose risks. We propose a novel approach using the SGP30 sensor to monitor cartridge effectiveness, aligned with PEL-TWA regulations. Our system triggers alerts when sensor readings exceed 10 ppm for toluene, 35 ppm for carbon monoxide, and 5000 ppm for carbon dioxide. Additionally, we incorporate physiological monitoring via Photoplethysmography (PPG) using the AFE4404 sensor to assess Heart Rate (HR) and Heart Rate Variability (HRV), alongside respiration monitoring with the D6F-P0010AM2 airflow sensor. Data from these sensors is transmitted via low-power Bluetooth to a mobile APP, enabling real-time monitoring of the wearer's condition. In case of cartridge failure or abnormal physiological readings, the APP triggers vibrations on the mask and automatically sends an SOS to the employer's server via UDP protocol, ensuring immediate intervention. This system aims to enhance occupational safety by reducing the risk of accidents and safeguarding worker well-being.

Authors

Institutions

Publication Details

Published
2024-10-06
DOI
https://doi.org/10.1109/smc54092.2024.10831057
Primary Topic
Industrial Vision Systems and Defect Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of Smart Mask System Integrated with Alert Detection and Vital-sign Measurement

Ren-Guey Lee, Chun-Chieh Hsiao, Wei-Lun Ting
Industrial Vision Systems and Defect Detection
article

Development of Smart Mask System Integrated with Alert Detection and Vital-sign Measurement

Ren-Guey Lee, Chun-Chieh Hsiao, Wei-Lun Ting
article en

Abstract

This research focuses on enhancing worker safety in environments with high levels of TVOC gases, such as toluene, a neurotoxin. Traditional cartridge replacement methods, based on fixed intervals, lack precision and pose risks. We propose a novel approach using the SGP30 sensor to monitor cartridge effectiveness, aligned with PEL-TWA regulations. Our system triggers alerts when sensor readings exceed 10 ppm for toluene, 35 ppm for carbon monoxide, and 5000 ppm for carbon dioxide. Additionally, we incorporate physiological monitoring via Photoplethysmography (PPG) using the AFE4404 sensor to assess Heart Rate (HR) and Heart Rate Variability (HRV), alongside respiration monitoring with the D6F-P0010AM2 airflow sensor. Data from these sensors is transmitted via low-power Bluetooth to a mobile APP, enabling real-time monitoring of the wearer's condition. In case of cartridge failure or abnormal physiological readings, the APP triggers vibrations on the mask and automatically sends an SOS to the employer's server via UDP protocol, ensuring immediate intervention. This system aims to enhance occupational safety by reducing the risk of accidents and safeguarding worker well-being.

National Taipei University of Technology (TW)
Openalex Percentile: Top 62%
Industrial Vision Systems and Defect Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.