An Improved Adaptive Moment Estimation Algorithm for the Industrial Robot Calibration
Within the context of intelligent manufacturing, industrial robots have a pivotal function. Nonetheless, extended operational periods cause a decline in their absolute positioning accuracy, preventing them from meeting high precision. To address this issue, this paper presents a novel robot algorithm that combines an adaptive and momental bound algorithm with decoupled weight decay (AdaModW), which has three-fold ideas: a) adopting an adaptive moment estimation (Adam) algorithm to achieve a high convergence rate, b) introducing a hyperparameter into the Adam algorithm to define the length of memory, effectively addressing the issue of the abnormal learning rate, and c) interpolating a weight decay coefficient to improve its generalization. Numerous experiments on an HRS-JR680 industrial robot show that the presented algorithm significantly outperforms state-of-the-art algorithms in robot calibration performance. Thus, in light of its reliability, this algorithm provides an efficient way to address robot calibration concerns.
Authors
- Tinghui Chen
- Shuai Li (ORCID: https://orcid.org/0009-0004-4499-0023)
Institutions
- Chongqing University of Posts and Telecommunications (CN)
- University of Oulu (FI)
Publication Details
- Published
- 2024-10-06
- DOI
- https://doi.org/10.1109/smc54092.2024.10831018
- Citations
- 1
- Primary Topic
- Advanced Vision and Imaging
- Type
- article
- Field-Weighted Citation Impact
- 0.25
Funders
- National Natural Science Foundation of China