EXPERIMENTAL STUDY OF COOLING FLUID VARIATION ON THE THERMOELECTRIC HOT SIDE ON THERMOELECTRIC VACCINE COOLER BOX PERFORMANCE
The advanced countries make health a high priority and collaborate to create a better quality of life. Vaccination is a critical component of global health. Vaccines must be stored at a constant temperature of 2-8℃, to maintain the viability of the vaccine cold chain. Thermoelectric cooling systems (TECs) are a solution that is simple, lightweight, low cost, and portable. Excessively high hot-side temperatures can be detrimental to operators and the environment during distribution processes. The application of fans and circulating fluid can reduce the TEC hot-side temperature. The lowest TEC temperature difference of 30.26℃ is achieved by using only a fan. The minimum hot side of 31.28℃ is achieved with the fan and circulating water model. The minimum cold side can be increased to 0.53℃ with the fan and circulating radiator coolant model. All tests were at vaccine-eligible temperatures. The best COP of 0.14 can be reached in this study.
Authors
- Novreza Pratama (ORCID: https://orcid.org/0009-0007-9718-1029)
- Hadi Wahyudi (ORCID: https://orcid.org/0000-0001-5915-5240)
- Imron Rosyadi (ORCID: https://orcid.org/0000-0002-4367-4166)
- Muhamad Haykal Fasya
Institutions
- Sebelas Maret University (ID)
- Sultan Ageng Tirtayasa University (ID)
Publication Details
- Journal
- Jurnal Rekayasa Mesin
- Published
- 2024-12-15
- DOI
- https://doi.org/10.21776/jrm.v15i3.1850
- Primary Topic
- Advanced Thermoelectric Materials and Devices
- Type
- article
- Field-Weighted Citation Impact
- 0.00