GENERALIZED DEFINITION OF THE APPARENT POWER AND ENERGY-EFFICIENT STRATEGIES OF ACTIVE FILTRATION IN THE REDUCED COORDINATE BASIS OF A MULTIPHASE POWER SUPPLY SYSTEM

The paper substantiates the equivalence of determining the apparent power of a multiphase power supply system with different transmission line impedances using the Fryze-Buchholz-Deppenbrock method and on a reduced coordinate basis. Two energy-efficient control strategies for shunt active filtering in the reduced coordinate basis are proposed. The first strategy provides a unit value of the power factor, and the second strategy minimizes power losses in the transmission line while maintaining symmetry and the quasi-sinusoidal shape of the consumed currents. The advantages of using a reduced coordinate basis are a reduction in the number of sensors and key active filter regulators as well as the absence of the problem to organize the artificial grounding point for phase voltage measurements. A correction factor for the apparent power and power factor formulas was determined and verified in the presence of restrictions on the symmetrical and sinusoidal shape of the consumed currents. References 22, figures 5, tables 2.

Authors

Institutions

Publication Details

Journal
Tekhnichna Elektrodynamika
Published
2025-01-09
DOI
https://doi.org/10.15407/techned2025.01.024
Primary Topic
Electric Power Systems and Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

GENERALIZED DEFINITION OF THE APPARENT POWER AND ENERGY-EFFICIENT STRATEGIES OF ACTIVE FILTRATION IN THE REDUCED COORDINATE BASIS OF A MULTIPHASE POWER SUPPLY SYSTEM

І.А. Shapoval, V.М. Mykhalskyi, V.V. Chopyk, S.Y. Polishchuk et al.
Tekhnichna Elektrodynamika
Electric Power Systems and Control
article

GENERALIZED DEFINITION OF THE APPARENT POWER AND ENERGY-EFFICIENT STRATEGIES OF ACTIVE FILTRATION IN THE REDUCED COORDINATE BASIS OF A MULTIPHASE POWER SUPPLY SYSTEM

І.А. Shapoval, V.М. Mykhalskyi, V.V. Chopyk, S.Y. Polishchuk, Yu.V. Kutafin, М.Yu. Artemenko
article en

Abstract

The paper substantiates the equivalence of determining the apparent power of a multiphase power supply system with different transmission line impedances using the Fryze-Buchholz-Deppenbrock method and on a reduced coordinate basis. Two energy-efficient control strategies for shunt active filtering in the reduced coordinate basis are proposed. The first strategy provides a unit value of the power factor, and the second strategy minimizes power losses in the transmission line while maintaining symmetry and the quasi-sinusoidal shape of the consumed currents. The advantages of using a reduced coordinate basis are a reduction in the number of sensors and key active filter regulators as well as the absence of the problem to organize the artificial grounding point for phase voltage measurements. A correction factor for the apparent power and power factor formulas was determined and verified in the presence of restrictions on the symmetrical and sinusoidal shape of the consumed currents. References 22, figures 5, tables 2.

Tekhnichna ElektrodynamikaVol. 2025(1)
Weatherford College (US)
Openalex Percentile: Top 99%
Electric Power Systems and Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

GENERALIZED DEFINITION OF THE APPARENT POWER AND ENERGY-EFFICIENT STRATEGIES OF ACTIVE FILTRATION IN THE REDUCED COORDINATE BASIS OF A MULTIPHASE POWER SUPPLY SYSTEM — І.А. Shapoval, V.М. Mykhalskyi, et al. · Tekhnichna Elektrodynamika (2025) | TGRS Research Map | TGRS