METHOD OF DETERMINING THE INSTALLED CAPACITY OF DISTRIBUTED GENERATION POWER PLANTS WITH RENEWABLE ENERGY SOURCES AND ENERGY STORAGE SYSTEM

The developed method, which consists in determining the installed power of distributed generation, in particular, a wind power plant, a solar power plant, a standby power plant and the technical parameters of an energy storage system, to ensure the security of the supply of electric energy to local consumers, is given. Achieving a balance between the daily amount of electricity produced by distributed generation and the amount of consumption ensures the determination of excess amounts of electricity, which mainly occur during periods of peak solar radiation and, accordingly, the required capacity of an energy storage system. According to the simulation results, it was determined that with the maximum daily consumption of electricity by local consumers during the year at the level of 96 MWh, the daily balance of electricity is achieved at the installed capacity of the wind power plant at the level of 3.6 MW; solar power plant is 14 MW; standby power plant is 3.7 MW and the nominal power of an four-hour energy storage system is 16 MW. References 3, figures 2, table 1.

Authors

Institutions

Publication Details

Journal
Tekhnichna Elektrodynamika
Published
2025-01-09
DOI
https://doi.org/10.15407/techned2025.01.065
Citations
6
Primary Topic
Renewable energy and sustainable power systems
Type
article
Field-Weighted Citation Impact
2.18
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

METHOD OF DETERMINING THE INSTALLED CAPACITY OF DISTRIBUTED GENERATION POWER PLANTS WITH RENEWABLE ENERGY SOURCES AND ENERGY STORAGE SYSTEM

Ihor Buratynskyi, Artur Zaporozhets
6 citations
Tekhnichna Elektrodynamika
Renewable energy and sustainable power systems
2.18
article

METHOD OF DETERMINING THE INSTALLED CAPACITY OF DISTRIBUTED GENERATION POWER PLANTS WITH RENEWABLE ENERGY SOURCES AND ENERGY STORAGE SYSTEM

Ihor Buratynskyi, Artur Zaporozhets
article en
6 citations

Abstract

The developed method, which consists in determining the installed power of distributed generation, in particular, a wind power plant, a solar power plant, a standby power plant and the technical parameters of an energy storage system, to ensure the security of the supply of electric energy to local consumers, is given. Achieving a balance between the daily amount of electricity produced by distributed generation and the amount of consumption ensures the determination of excess amounts of electricity, which mainly occur during periods of peak solar radiation and, accordingly, the required capacity of an energy storage system. According to the simulation results, it was determined that with the maximum daily consumption of electricity by local consumers during the year at the level of 96 MWh, the daily balance of electricity is achieved at the installed capacity of the wind power plant at the level of 3.6 MW; solar power plant is 14 MW; standby power plant is 3.7 MW and the nominal power of an four-hour energy storage system is 16 MW. References 3, figures 2, table 1.

Tekhnichna ElektrodynamikaVol. 2025(1)
Weatherford College (US)
Openalex Percentile: Top 14%
Renewable energy and sustainable power systems
2.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

METHOD OF DETERMINING THE INSTALLED CAPACITY OF DISTRIBUTED GENERATION POWER PLANTS WITH RENEWABLE ENERGY SOURCES AND ENERGY STORAGE SYSTEM — Ihor Buratynskyi, Artur Zaporozhets · Tekhnichna Elektrodynamika (2025) | TGRS Research Map | TGRS