A Three-phase Unified AC Power Quality Control Device

This article studies the design method of inverter power circuit for three-phase unified AC power quality control device, and designs IGBT buffer circuit and driving circuit, as well as the DC link overvoltage protection and inverter AC side overcurrent protection circuit of the entire system. Finally, the joint amplitude waveform and joint experimental waveform of the entire experimental device were presented. Simulation and experimental research results showed that the three-phase unified AC power quality regulation device can achieve the functions of eliminating load reactive power and harmonic current, and bi-directional adjustment of load voltage. The designed experimental system can meet the design requirements, and the control method of separately controlling the series voltage regulation link and the parallel active filtering link is reasonable. The results show that the detection method is effective. And experimental research was conducted on the designed parallel active filter, and the results showed that it can effectively eliminate load harmonics and reactive currents, and can meet the design requirements.

Authors

Institutions

Publication Details

Published
2024-08-14
DOI
https://doi.org/10.1109/peeec63877.2024.00007
Primary Topic
Electric Power Systems and Control
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Three-phase Unified AC Power Quality Control Device

Ling Zhou, Yichi Liu, Yuan Ji, Fangquan Wu
Electric Power Systems and Control
article

A Three-phase Unified AC Power Quality Control Device

Ling Zhou, Yichi Liu, Yuan Ji, Fangquan Wu
article en

Abstract

This article studies the design method of inverter power circuit for three-phase unified AC power quality control device, and designs IGBT buffer circuit and driving circuit, as well as the DC link overvoltage protection and inverter AC side overcurrent protection circuit of the entire system. Finally, the joint amplitude waveform and joint experimental waveform of the entire experimental device were presented. Simulation and experimental research results showed that the three-phase unified AC power quality regulation device can achieve the functions of eliminating load reactive power and harmonic current, and bi-directional adjustment of load voltage. The designed experimental system can meet the design requirements, and the control method of separately controlling the series voltage regulation link and the parallel active filtering link is reasonable. The results show that the detection method is effective. And experimental research was conducted on the designed parallel active filter, and the results showed that it can effectively eliminate load harmonics and reactive currents, and can meet the design requirements.

Guizhou Electric Power Design and Research Institute (CN)
Technology Development
Affordable and clean energy
Openalex Percentile: Top 76%
Electric Power Systems and Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.