Modified micro test tubes as a promising basis for immobilization of antibodies for immunocapture on the example of SARS-CoV-2

The solid-phase immunocapture with antibodies is an important tool used in immunology studies, but conventional polystyrene plates are prone to deformation during thermal cycling and cross-contamination of samples, which reduces accuracy and reproducibility, when molecular genetic testing methods are included in the study. The development of alternative solutions, such as modified polystyrene-coated polypropylene tubes, makes it possible to eliminate these limitations. The study aimed to create a new approach to SARS-CoV-2 immunocapture involving the use of modified test tubes and to assess its efficacy. Monoclonal antibodies P2C5 and R107, as well as inactivated strains GК2020/1 (Wuhan) and hCoV-19/Russia/MOW-PMVL-51/2021 (Omicron) were used for analysis. Immobilization of antibodies, sorption of viral particles, and RNA extraction were accomplished using modified test tubes, standard plates, and uncoated test tubes. The key findings showed that the polystyrene-coated modified test tubes ensured better immunocapture compared to the plates (p < 0.0001), especially when using the P2C5 antibody effective against various SARS-CoV-2 lineages, including Omicron. The R107 antibody showed limited specificity, not exceeding that of the control group with bovine serum albumin. The cross-contamination analysis revealed contamination of 14 samples out of 288 in the plates, while no contamination of samples was reported for modified test tubes. Thus, modified test tubes used for high-precision molecular testing have some advantages, since these decrease the risk of cross-contamination and improve immunocapture efficacy.

Authors

Institutions

Publication Details

Journal
Bulletin of Russian State Medical University
Published
2024-12-01
DOI
https://doi.org/10.24075/brsmu.2024.068
Primary Topic
SARS-CoV-2 and COVID-19 Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Modified micro test tubes as a promising basis for immobilization of antibodies for immunocapture on the example of SARS-CoV-2

R. O. Abdrakhmanova, I. A. FAVORSKAYA, Dmitry V. Shcheblyakov, Vladimir А. Gushchin et al.
Bulletin of Russian State Medical University
SARS-CoV-2 and COVID-19 Research
article

Modified micro test tubes as a promising basis for immobilization of antibodies for immunocapture on the example of SARS-CoV-2

R. O. Abdrakhmanova, I. A. FAVORSKAYA, Dmitry V. Shcheblyakov, Vladimir А. Gushchin, G. R. Baeva, T. S. Rubalskaya, S. V. Poroisky, E.O. Roubalsky, M.V. Lazko
article en

Abstract

The solid-phase immunocapture with antibodies is an important tool used in immunology studies, but conventional polystyrene plates are prone to deformation during thermal cycling and cross-contamination of samples, which reduces accuracy and reproducibility, when molecular genetic testing methods are included in the study. The development of alternative solutions, such as modified polystyrene-coated polypropylene tubes, makes it possible to eliminate these limitations. The study aimed to create a new approach to SARS-CoV-2 immunocapture involving the use of modified test tubes and to assess its efficacy. Monoclonal antibodies P2C5 and R107, as well as inactivated strains GК2020/1 (Wuhan) and hCoV-19/Russia/MOW-PMVL-51/2021 (Omicron) were used for analysis. Immobilization of antibodies, sorption of viral particles, and RNA extraction were accomplished using modified test tubes, standard plates, and uncoated test tubes. The key findings showed that the polystyrene-coated modified test tubes ensured better immunocapture compared to the plates (p < 0.0001), especially when using the P2C5 antibody effective against various SARS-CoV-2 lineages, including Omicron. The R107 antibody showed limited specificity, not exceeding that of the control group with bovine serum albumin. The cross-contamination analysis revealed contamination of 14 samples out of 288 in the plates, while no contamination of samples was reported for modified test tubes. Thus, modified test tubes used for high-precision molecular testing have some advantages, since these decrease the risk of cross-contamination and improve immunocapture efficacy.

Bulletin of Russian State Medical University(2024(6))
Gamalei Institute of Epidemiology and Microbiology (RU), Astrakhan State Medical University (RU), Federal Service for Surveillance on Consumer Rights Protection and Human Wellbeing (RU)
Openalex Percentile: Top 69%
SARS-CoV-2 and COVID-19 Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.