Comparison of classical and flowcytometric osmotic fragility and flowcytometric eosin-5-maleimide binding tests in diagnosis of hereditary spherocytosis

Abstract Objectives Hereditary spherocytosis (HS) is the most common congenital hemolytic anemia in Northern Europe and North America. Damaged or deficient proteins in the erythrocyte membrane cause the condition, leading to a decrease in the surface area and volume of erythrocytes. Specialists traditionally use the osmotic fragility test (C-OF) for diagnosis. Researchers have developed new methods for flow cytometry-based tests that are the eosin-5-maleimide binding (EMA) and osmotic fragility (FC-OF) tests. In this study, we aimed to determine and compare the power of discrimination of FC-OF, EMA, and C-OF tests. Another purpose is to investigate the effect of incubation. Methods We performed both real-time and incubated C-OF, EMA, and FC-OF on 20 patients diagnosed with HS and 30 healthy controls. We diagnosed HS based on family history, spherocytes, and clinical and lab findings. Results We found that the success of all tests in the classification was statistically significant (p<0.001). The discriminatory power of C-OF was not different from that of EMA and FC-OF. FC-OF discriminated better than EMA. Incubation increased C-OF performance and decreased EMA and FC-OF performance. Conclusions We think FC-OF should be preferred. Because it has higher discrimination power, specificity, and sensitivity. It gives faster results, costs less, and needs less labor. The lack of flow cytometer devices in every center is the biggest handicap of FC-OF and EMA. But we think that the FC-OF method can be adapted to hemogram devices available in every center in the future.

Authors

Institutions

Publication Details

Journal
Turkish Journal of Biochemistry
Published
2025-01-16
DOI
https://doi.org/10.1515/tjb-2024-0197
Primary Topic
Erythrocyte Function and Pathophysiology
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of classical and flowcytometric osmotic fragility and flowcytometric eosin-5-maleimide binding tests in diagnosis of hereditary spherocytosis

Gülhan Örekici Temel, Anıl Tombak, Cemil Gülüm, Selma Ünal et al.
Turkish Journal of Biochemistry
Erythrocyte Function and Pathophysiology
article

Comparison of classical and flowcytometric osmotic fragility and flowcytometric eosin-5-maleimide binding tests in diagnosis of hereditary spherocytosis

Gülhan Örekici Temel, Anıl Tombak, Cemil Gülüm, Selma Ünal, Pelin Eroğlu
article en

Abstract

Abstract Objectives Hereditary spherocytosis (HS) is the most common congenital hemolytic anemia in Northern Europe and North America. Damaged or deficient proteins in the erythrocyte membrane cause the condition, leading to a decrease in the surface area and volume of erythrocytes. Specialists traditionally use the osmotic fragility test (C-OF) for diagnosis. Researchers have developed new methods for flow cytometry-based tests that are the eosin-5-maleimide binding (EMA) and osmotic fragility (FC-OF) tests. In this study, we aimed to determine and compare the power of discrimination of FC-OF, EMA, and C-OF tests. Another purpose is to investigate the effect of incubation. Methods We performed both real-time and incubated C-OF, EMA, and FC-OF on 20 patients diagnosed with HS and 30 healthy controls. We diagnosed HS based on family history, spherocytes, and clinical and lab findings. Results We found that the success of all tests in the classification was statistically significant (p<0.001). The discriminatory power of C-OF was not different from that of EMA and FC-OF. FC-OF discriminated better than EMA. Incubation increased C-OF performance and decreased EMA and FC-OF performance. Conclusions We think FC-OF should be preferred. Because it has higher discrimination power, specificity, and sensitivity. It gives faster results, costs less, and needs less labor. The lack of flow cytometer devices in every center is the biggest handicap of FC-OF and EMA. But we think that the FC-OF method can be adapted to hemogram devices available in every center in the future.

Turkish Journal of BiochemistryVol. 50(1)
Mersin Üniversitesi (TR)
Mersin Üniversitesi
Openalex Percentile: Top 99%
Erythrocyte Function and Pathophysiology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comparison of classical and flowcytometric osmotic fragility and flowcytometric eosin-5-maleimide binding tests in diagnosis of hereditary spherocytosis — Gülhan Örekici Temel, Anıl Tombak, et al. · Turkish Journal of Biochemistry (2025) | TGRS Research Map | TGRS