Thermal performance analysis of a heat pump-based energy system to meet heating and cooling demand of residential buildings

The building sector significantly impacts greenhouse gas emissions, making decarbonisation of heating and cooling essential for achieving carbon neutrality. Replacing conventional fossil fuel technologies with low-carbon alternatives like reversible heat pumps (HPs), alongside integrating thermal energy storage systems, can provide flexibility by reducing thermal demand during peak hours—which could also be reflected in economic savings. In view of this, the detailed dynamic model of an energy system based on a reversible HP integrated with thermal stores is presented in this paper. The adopted configuration has been designed to meet not only heat demand during cold months, but also cooling demand over summer, which is expected to increase in future years according to climate projections. A multi-zone modelling approach was employed to simulate a residential building. Internal heat gains due to appliances, lighting, and occupancy schedules were incorporated in the model to accurately represent the zonal temperature level control in the thermal envelope. The performance of the energy system utilising the reversible HP was compared to when a gas boiler is used, demonstrating the capabilities of low-carbon technologies to meet thermal demand during different seasons of the year. Moreover, the performance of HP-based system under extreme weather conditions was evaluated. The HP configuration consumed 1.15–2.34 times less monthly energy to meet the thermal needs compared to the boiler-based system. The inclusion of internal heat gains showed a considerable effect, with a monthly energy consumption increment of up to 63.5 % observed for the HP-based energy system. • A dynamic model of a heat pump-based energy supply technology is developed. • The multi-zone modelling approach is adopted to simulate a terraced house in Wales. • Internal heat gain due to appliances, lighting, and occupancy schedule is modelled. • The heat pump system uses ∼1.6 times less energy annually compared to a gas boiler. • Internal heat gains affect the heat pump's annual energy consumption by 15.5 %.

Authors

Institutions

Publication Details

Journal
Applied Energy
Published
2025-01-16
DOI
https://doi.org/10.1016/j.apenergy.2025.125306
Citations
24
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
24.15

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thermal performance analysis of a heat pump-based energy system to meet heating and cooling demand of residential buildings

Arslan Saleem, Carlos E. Ugalde‐Loo
24 citations
Applied Energy
Building Energy and Comfort Optimization
24.15
article

Thermal performance analysis of a heat pump-based energy system to meet heating and cooling demand of residential buildings

Arslan Saleem, Carlos E. Ugalde‐Loo
article en
24 citations

Abstract

The building sector significantly impacts greenhouse gas emissions, making decarbonisation of heating and cooling essential for achieving carbon neutrality. Replacing conventional fossil fuel technologies with low-carbon alternatives like reversible heat pumps (HPs), alongside integrating thermal energy storage systems, can provide flexibility by reducing thermal demand during peak hours—which could also be reflected in economic savings. In view of this, the detailed dynamic model of an energy system based on a reversible HP integrated with thermal stores is presented in this paper. The adopted configuration has been designed to meet not only heat demand during cold months, but also cooling demand over summer, which is expected to increase in future years according to climate projections. A multi-zone modelling approach was employed to simulate a residential building. Internal heat gains due to appliances, lighting, and occupancy schedules were incorporated in the model to accurately represent the zonal temperature level control in the thermal envelope. The performance of the energy system utilising the reversible HP was compared to when a gas boiler is used, demonstrating the capabilities of low-carbon technologies to meet thermal demand during different seasons of the year. Moreover, the performance of HP-based system under extreme weather conditions was evaluated. The HP configuration consumed 1.15–2.34 times less monthly energy to meet the thermal needs compared to the boiler-based system. The inclusion of internal heat gains showed a considerable effect, with a monthly energy consumption increment of up to 63.5 % observed for the HP-based energy system. • A dynamic model of a heat pump-based energy supply technology is developed. • The multi-zone modelling approach is adopted to simulate a terraced house in Wales. • Internal heat gain due to appliances, lighting, and occupancy schedule is modelled. • The heat pump system uses ∼1.6 times less energy annually compared to a gas boiler. • Internal heat gains affect the heat pump's annual energy consumption by 15.5 %.

Applied EnergyVol. 383
Cardiff University (GB)
Engineering and Physical Sciences Research Council
Affordable and clean energy
Openalex Percentile: Top 0%
Building Energy and Comfort Optimization
24.15
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.