Array Coil Design and Experimental Verification for Separation of Tower Grounding Pulsed Eddy Current Excitation and Response Magnetic Field Signals

Transmission line towers play an important role in power transmission, and the assessment of transmission line tower grounding by pulsed eddy current detection technology is conducive to the safe and reliable operation of power transmission. Aiming at the problem that the primary and secondary magnetic fields of the traditional pulsed eddy current transmitting coil structure overlap, resulting in the loss of shallow information, this paper first discusses the loss of shallow information caused by the aliasing of the magnetic field under the non-zero current shutdown effect, and then analyzes the traditional weak magnetic field coupling separation principle, and proposes the array coil structure of this paper based on the magnetic field vector destructive separation principle. Subsequently, the corresponding finite element simulation model was established, and the magnetic field distribution, magnetic field size, induced voltage, and mutual inductance coefficient of the array coil and the traditional center loop structure at the receiving coil were compared in the static field. In the transient field, the response signal of the array coil structure with or without the grounding body and the receiving coil is equidistant was simulated. The simulation results show that, under the same excitation, the vector coil array structure can greatly reduce the mutual inductance coefficient between the excitation and transmitting coils, reduce the influence of the primary magnetic field of the excitation coil on the receiving coil, and avoid the loss of shallow information. Finally, experimental tests were carried out on different tower grounding bodies. The experimental results at different measuring points prove that the array coil structure proposed in this paper can separate well the magnetic field generated by the excitation signal, improve the effective resolution time, avoid the loss of shallow information, and improve the operational stability of power transmission systems.

Authors

Institutions

Publication Details

Journal
Energies
Published
2025-01-16
DOI
https://doi.org/10.3390/en18020364
Citations
1
Primary Topic
Non-Destructive Testing Techniques
Type
article
Field-Weighted Citation Impact
0.71
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Array Coil Design and Experimental Verification for Separation of Tower Grounding Pulsed Eddy Current Excitation and Response Magnetic Field Signals

Xiaotian Wang, Zhiwu Zeng, Zhichi Lin, Xinxun Wang et al.
1 citations
Energies
Non-Destructive Testing Techniques
0.71
article

Array Coil Design and Experimental Verification for Separation of Tower Grounding Pulsed Eddy Current Excitation and Response Magnetic Field Signals

Xiaotian Wang, Zhiwu Zeng, Zhichi Lin, Xinxun Wang, Fan Gan, Zheng Guo, Tian Xu, Jingang Wang, Wei Zhu, Yuhua Zuo
article en
1 citations

Abstract

Transmission line towers play an important role in power transmission, and the assessment of transmission line tower grounding by pulsed eddy current detection technology is conducive to the safe and reliable operation of power transmission. Aiming at the problem that the primary and secondary magnetic fields of the traditional pulsed eddy current transmitting coil structure overlap, resulting in the loss of shallow information, this paper first discusses the loss of shallow information caused by the aliasing of the magnetic field under the non-zero current shutdown effect, and then analyzes the traditional weak magnetic field coupling separation principle, and proposes the array coil structure of this paper based on the magnetic field vector destructive separation principle. Subsequently, the corresponding finite element simulation model was established, and the magnetic field distribution, magnetic field size, induced voltage, and mutual inductance coefficient of the array coil and the traditional center loop structure at the receiving coil were compared in the static field. In the transient field, the response signal of the array coil structure with or without the grounding body and the receiving coil is equidistant was simulated. The simulation results show that, under the same excitation, the vector coil array structure can greatly reduce the mutual inductance coefficient between the excitation and transmitting coils, reduce the influence of the primary magnetic field of the excitation coil on the receiving coil, and avoid the loss of shallow information. Finally, experimental tests were carried out on different tower grounding bodies. The experimental results at different measuring points prove that the array coil structure proposed in this paper can separate well the magnetic field generated by the excitation signal, improve the effective resolution time, avoid the loss of shallow information, and improve the operational stability of power transmission systems.

EnergiesVol. 18(2)
Chongqing University (CN), State Grid Corporation of China (China) (CN), Guizhou Electric Power Design and Research Institute (CN)
Openalex Percentile: Top 37%
Non-Destructive Testing Techniques
0.71
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.