Integral UV Spectrophotometric Methods for Determination of Clopidogrel Bisulphate and Metamizole Sodium in Rinse Waters from Industrial Equipment

In this paper, methods for the determination of clopidogrel bisulphate and metamizole sodium in rinse waters from industrial equipment, using multiwavelength UV spectrometry and the calculation of areas under curves, are proposed. Spectra were recorded in an aqueous medium without preliminary pH adjustment. A numerical integration of the spectra was performed in the wavelength range of 210 to 290 nm for clopidogrel bisulphate, and 220 to 320 nm for metamizole sodium. The methods enable the determination of clopidogrel bisulphate and metamizole sodium in solution in the concentration range of 1–100 mg/L, do not require lengthy sample preparation and complex analytical equipment, and are suitable for the routine determination of these drugs in rinse waters from industrial equipment.

Authors

Institutions

Publication Details

Journal
Spectroscopy Journal
Published
2025-01-16
DOI
https://doi.org/10.3390/spectroscj3010002
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Integral UV Spectrophotometric Methods for Determination of Clopidogrel Bisulphate and Metamizole Sodium in Rinse Waters from Industrial Equipment

Pavel Anatolyevich Nikolaychuk
Spectroscopy Journal
Analytical Methods in Pharmaceuticals
article

Integral UV Spectrophotometric Methods for Determination of Clopidogrel Bisulphate and Metamizole Sodium in Rinse Waters from Industrial Equipment

Pavel Anatolyevich Nikolaychuk
article en

Abstract

In this paper, methods for the determination of clopidogrel bisulphate and metamizole sodium in rinse waters from industrial equipment, using multiwavelength UV spectrometry and the calculation of areas under curves, are proposed. Spectra were recorded in an aqueous medium without preliminary pH adjustment. A numerical integration of the spectra was performed in the wavelength range of 210 to 290 nm for clopidogrel bisulphate, and 220 to 320 nm for metamizole sodium. The methods enable the determination of clopidogrel bisulphate and metamizole sodium in solution in the concentration range of 1–100 mg/L, do not require lengthy sample preparation and complex analytical equipment, and are suitable for the routine determination of these drugs in rinse waters from industrial equipment.

Spectroscopy JournalVol. 3(1)
Kurgan State University (RU)
Openalex Percentile: Top 99%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Integral UV Spectrophotometric Methods for Determination of Clopidogrel Bisulphate and Metamizole Sodium in Rinse Waters from Industrial Equipment — Pavel Anatolyevich Nikolaychuk · Spectroscopy Journal (2025) | TGRS Research Map | TGRS