Zeolite-assisted Silica Substrate for Sensing Abdominal Aortic Aneurysms by Aptamer-C-reactive Protein-antibody Sandwich

Introduction: Identifying abdominal aortic aneurysm (AAA) and its condition is crucial for providing better treatment before rupture. Since AAA is often asymptomatic, regular monitoring is necessary for elderly individuals to detect changes in the aorta. Methods: Although imaging techniques are commonly used to diagnose AAA, they are expensive and can cause discomfort to patients. C-reactive protein (CRP) is an acute-phase protein, and its concentration is highly correlated with the size of the abdominal aortic aneurysm (AAA) diameter. It was found that patients with elevated CRP levels above 1.4 mg/mL had an AAA expansion rate of 4.8 mM, compared to 3.9 mM in those with levels below 1.4 mg/mL. In addition, CRP helps to identify AAA in asymptomatic patients. Compared to other biomarkers, CRP levels are useful in assessing the size of AAA. Results: Therefore, quantifying CRP levels aids in identifying and monitoring AAA size. This research focuses on developing a CRP biosensor on a zeolite-modified electrode with a silica substrate for diagnosing AAA. An anti-CRP aptamer serves as the capture molecule, while an anti-CRP antibody functions as the detection molecule. The aptamer is conjugated with gold nanoparticles and linked to the electrode via an amine-modified zeolite to enhance aptamer immobilization. Conclusion: Using an aptamer-antibody sandwich assay, a detection limit of 1 pg/mL of CRP was achieved on this surface. Furthermore, CRP-spiked serum samples showed a noticeable increase in current responses, while control proteins and complementary aptamers failed to elevate the current level, indicating the selective and specific detection of CRP.

Authors

Institutions

Publication Details

Journal
Current Nanoscience
Published
2025-01-16
DOI
https://doi.org/10.2174/0115734137331819241129072746
Primary Topic
Advanced Nanomaterials in Catalysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Zeolite-assisted Silica Substrate for Sensing Abdominal Aortic Aneurysms by Aptamer-C-reactive Protein-antibody Sandwich

Hong Jiang, Liwei Zhang, Long Yu, Xia Qian et al.
Current Nanoscience
Advanced Nanomaterials in Catalysis
article

Zeolite-assisted Silica Substrate for Sensing Abdominal Aortic Aneurysms by Aptamer-C-reactive Protein-antibody Sandwich

Hong Jiang, Liwei Zhang, Long Yu, Xia Qian, Subash C.B. Gopinath
article en

Abstract

Introduction: Identifying abdominal aortic aneurysm (AAA) and its condition is crucial for providing better treatment before rupture. Since AAA is often asymptomatic, regular monitoring is necessary for elderly individuals to detect changes in the aorta. Methods: Although imaging techniques are commonly used to diagnose AAA, they are expensive and can cause discomfort to patients. C-reactive protein (CRP) is an acute-phase protein, and its concentration is highly correlated with the size of the abdominal aortic aneurysm (AAA) diameter. It was found that patients with elevated CRP levels above 1.4 mg/mL had an AAA expansion rate of 4.8 mM, compared to 3.9 mM in those with levels below 1.4 mg/mL. In addition, CRP helps to identify AAA in asymptomatic patients. Compared to other biomarkers, CRP levels are useful in assessing the size of AAA. Results: Therefore, quantifying CRP levels aids in identifying and monitoring AAA size. This research focuses on developing a CRP biosensor on a zeolite-modified electrode with a silica substrate for diagnosing AAA. An anti-CRP aptamer serves as the capture molecule, while an anti-CRP antibody functions as the detection molecule. The aptamer is conjugated with gold nanoparticles and linked to the electrode via an amine-modified zeolite to enhance aptamer immobilization. Conclusion: Using an aptamer-antibody sandwich assay, a detection limit of 1 pg/mL of CRP was achieved on this surface. Furthermore, CRP-spiked serum samples showed a noticeable increase in current responses, while control proteins and complementary aptamers failed to elevate the current level, indicating the selective and specific detection of CRP.

Current NanoscienceVol. 22(1)
General Hospital of Shenyang Military Region (CN), Universiti Malaysia Perlis (MY), Saveetha University (IN)
Openalex Percentile: Top 99%
Advanced Nanomaterials in Catalysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.