Design of Wearable Fall Detection System

Falling has become one of the greatest threats to the physical health of the elderly. Accurately predicting the risk of falling and timely and effective detection of falls are very important. The application of wearable devices in fall detection is receiving increasing attention. This paper uses the small biomedical sensor mpu9150 to collect three-axis acceleration data of the human body, and then uses neural networks to train a fall detection model based on the three-axis acceleration. Additionally, simulated fall experiments were conducted on 30 volunteers in a laboratory environment to build a fall database. The experimental results show that the accuracy of the fall detection system is 95.8%. The system designed in this paper has the features of wearability, miniaturization, low power consumption, and high accuracy, and is suitable for multiple fields such as sports monitoring and high-risk operations.

Authors

Institutions

Publication Details

Published
2024-09-23
DOI
https://doi.org/10.1109/icedcs64328.2024.00009
Primary Topic
Context-Aware Activity Recognition Systems
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design of Wearable Fall Detection System

Xiaoqiang Ji, Meijiao Wang, Qi Sun
Context-Aware Activity Recognition Systems
article

Design of Wearable Fall Detection System

Xiaoqiang Ji, Meijiao Wang, Qi Sun
article en

Abstract

Falling has become one of the greatest threats to the physical health of the elderly. Accurately predicting the risk of falling and timely and effective detection of falls are very important. The application of wearable devices in fall detection is receiving increasing attention. This paper uses the small biomedical sensor mpu9150 to collect three-axis acceleration data of the human body, and then uses neural networks to train a fall detection model based on the three-axis acceleration. Additionally, simulated fall experiments were conducted on 30 volunteers in a laboratory environment to build a fall database. The experimental results show that the accuracy of the fall detection system is 95.8%. The system designed in this paper has the features of wearability, miniaturization, low power consumption, and high accuracy, and is suitable for multiple fields such as sports monitoring and high-risk operations.

Changchun University of Science and Technology (CN), Changchun Institute of Technology (CN)
Technology Development
Openalex Percentile: Top 74%
Context-Aware Activity Recognition Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Design of Wearable Fall Detection System — Xiaoqiang Ji, Meijiao Wang, et al. · (2024) | TGRS Research Map | TGRS