IEC60870-5-104 protocol abnormal behavior identification method based on service logic

IEC60870-5-104 (IEC 104 for short) protocol is widely used in the electric power industry, mainly for the communication between the master station and the sub-station. At present, the attack detection of IEC 104 protocol in the industry is mainly based on the traffic analysis of protocol characteristics and packet field content, and fails to fully consider the service logic, so it is difficult to effectively identify the electric power service packet attack. To solve this problem, this paper proposes a method of abnormal behavior recognition based on service logic. The method firstly analyzes the IEC 104 protocol layer by layer to realize the full parsing of application layer packets and the precise identification of service instructions. Secondly, on the basis of in-depth analysis of the normal service behavior mode of the protocol, a detection model based on the service timing logic and the service behavior baseline is constructed, which can effectively identify the service packet attack against the IEC 104 protocol.

Authors

Institutions

Publication Details

Published
2024-09-23
DOI
https://doi.org/10.1109/icedcs64328.2024.00055
Primary Topic
Smart Grid and Power Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

IEC60870-5-104 protocol abnormal behavior identification method based on service logic

Jinyu Wu, Dingbo Wang, Peize Wu
Smart Grid and Power Systems
article

IEC60870-5-104 protocol abnormal behavior identification method based on service logic

Jinyu Wu, Dingbo Wang, Peize Wu
article en

Abstract

IEC60870-5-104 (IEC 104 for short) protocol is widely used in the electric power industry, mainly for the communication between the master station and the sub-station. At present, the attack detection of IEC 104 protocol in the industry is mainly based on the traffic analysis of protocol characteristics and packet field content, and fails to fully consider the service logic, so it is difficult to effectively identify the electric power service packet attack. To solve this problem, this paper proposes a method of abnormal behavior recognition based on service logic. The method firstly analyzes the IEC 104 protocol layer by layer to realize the full parsing of application layer packets and the precise identification of service instructions. Secondly, on the basis of in-depth analysis of the normal service behavior mode of the protocol, a detection model based on the service timing logic and the service behavior baseline is constructed, which can effectively identify the service packet attack against the IEC 104 protocol.

China Southern Power Grid (China) (CN)
Reduced inequalities
Openalex Percentile: Top 76%
Smart Grid and Power Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

IEC60870-5-104 protocol abnormal behavior identification method based on service logic — Jinyu Wu, Dingbo Wang, et al. · (2024) | TGRS Research Map | TGRS