Identification of a Turn-to-Turn Short Circuit in a Transformer Winding

Power transformers with a high voltage of 10 kV and low voltage of 0.4 kV are the most widely used in the electric power industry. According to the annual statistics on power transformer failures, the largest number of power transformer accidents occurs due to a turn-to-turn short circuit, the consequences of which can either render the transformer inoperative and require major repairs, or require its complete replacement, which makes the task of monitoring and forecasting the condition and ability to operate transformer windings one of the most pressing. The “direct current decay test” is adopted as a tool, since it has a number of advantages compared to other tools and methods that require the availability of appropriate and complex-to-use equipment, as well as sufficiently qualified personnel to use such methods and tools. Based on the theory of conducting a direct current decay test, a hardware and software complex was assembled and test modes were determined. The parameters of the transformer equivalent circuit were obtained and identified. High accuracy of the selected method in determining the development of a turn-to-turn short circuit in the transformer windings was shown.

Authors

Institutions

Publication Details

Published
2024-11-12
DOI
https://doi.org/10.1109/dynamics64718.2024.10838643
Primary Topic
Magnetic Properties and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Identification of a Turn-to-Turn Short Circuit in a Transformer Winding

V. V. Anikin, Ruslan V. Saifullin, Vladimir Bedinov
Magnetic Properties and Applications
article

Identification of a Turn-to-Turn Short Circuit in a Transformer Winding

V. V. Anikin, Ruslan V. Saifullin, Vladimir Bedinov
article en

Abstract

Power transformers with a high voltage of 10 kV and low voltage of 0.4 kV are the most widely used in the electric power industry. According to the annual statistics on power transformer failures, the largest number of power transformer accidents occurs due to a turn-to-turn short circuit, the consequences of which can either render the transformer inoperative and require major repairs, or require its complete replacement, which makes the task of monitoring and forecasting the condition and ability to operate transformer windings one of the most pressing. The “direct current decay test” is adopted as a tool, since it has a number of advantages compared to other tools and methods that require the availability of appropriate and complex-to-use equipment, as well as sufficiently qualified personnel to use such methods and tools. Based on the theory of conducting a direct current decay test, a hardware and software complex was assembled and test modes were determined. The parameters of the transformer equivalent circuit were obtained and identified. High accuracy of the selected method in determining the development of a turn-to-turn short circuit in the transformer windings was shown.

Yugra State University (RU)
Affordable and clean energy
Openalex Percentile: Top 85%
Magnetic Properties and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.