Fault-Tolerant Control With Faulty Phase Winding Currents Compensation for Current Source Inverter-Fed Five-Phase PMSM Under Adjacent Double-Phase Open-Circuit Fault

Multiphase permanent magnet synchronous motors (PMSMs) driven by the current source inverters (CSIs) are widely used in safety-critical applications, due to their fault-tolerant capability and high torque/power density. Nevertheless, the fault-tolerant field-oriented control method based on reduced order transformation matrices for addressing the adjacent double-phase open-circuit fault (ADP-OCF) in the CSI has not yet been established. Moreover, the influence of faulty phase winding currents has not been analyzed and suppressed. Hence, this article develops a fault-tolerant control approach that includes compensation for faulty phase winding currents in the case of ADP-OCF in the CSI. First, the optimized fault-tolerant winding currents are derived. Subsequently, the decoupled mathematical model and fault-tolerant space-vector-pulsewidth-modulation (PWM) strategy are established, and finally the fault-tolerant control is achieved. The effectiveness of the proposed fault-tolerant control scheme has been validated in the experimental results. Additionally, the utilization of compensating for faulty phase winding currents can lead to a further reduction in electromagnetic torque ripple by 19.32%.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Transportation Electrification
Published
2025-01-16
DOI
https://doi.org/10.1109/tte.2025.3530522
Citations
7
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
5.11
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fault-Tolerant Control With Faulty Phase Winding Currents Compensation for Current Source Inverter-Fed Five-Phase PMSM Under Adjacent Double-Phase Open-Circuit Fault

Xiaoyong Sun, Zhen Chen, Z. Q. Zhu, Xiangdong Liu et al.
7 citations
IEEE Transactions on Transportation Electrification
HVDC Systems and Fault Protection
5.11
article

Fault-Tolerant Control With Faulty Phase Winding Currents Compensation for Current Source Inverter-Fed Five-Phase PMSM Under Adjacent Double-Phase Open-Circuit Fault

Xiaoyong Sun, Zhen Chen, Z. Q. Zhu, Xiangdong Liu, Chao Chen
article en
7 citations

Abstract

Multiphase permanent magnet synchronous motors (PMSMs) driven by the current source inverters (CSIs) are widely used in safety-critical applications, due to their fault-tolerant capability and high torque/power density. Nevertheless, the fault-tolerant field-oriented control method based on reduced order transformation matrices for addressing the adjacent double-phase open-circuit fault (ADP-OCF) in the CSI has not yet been established. Moreover, the influence of faulty phase winding currents has not been analyzed and suppressed. Hence, this article develops a fault-tolerant control approach that includes compensation for faulty phase winding currents in the case of ADP-OCF in the CSI. First, the optimized fault-tolerant winding currents are derived. Subsequently, the decoupled mathematical model and fault-tolerant space-vector-pulsewidth-modulation (PWM) strategy are established, and finally the fault-tolerant control is achieved. The effectiveness of the proposed fault-tolerant control scheme has been validated in the experimental results. Additionally, the utilization of compensating for faulty phase winding currents can lead to a further reduction in electromagnetic torque ripple by 19.32%.

IEEE Transactions on Transportation ElectrificationVol. 11(3)
Beijing Institute of Technology (CN), University of Sheffield (GB)
Affordable and clean energy
Openalex Percentile: Top 5%
HVDC Systems and Fault Protection
5.11
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Fault-Tolerant Control With Faulty Phase Winding Currents Compensation for Current Source Inverter-Fed Five-Phase PMSM Under Adjacent Double-Phase Open-Circuit Fault — Xiaoyong Sun, Zhen Chen, et al. · IEEE Transactions on Transportation Electrification (2025) | TGRS Research Map | TGRS