Performance of a VCR System with Variable Capillary Tube Geometry and R134a Refrigerant Charge Through Forced Convection at Various Air Velocities

Refrigerators are now considered to be the most vital component of modern life.The primary criterion is energy usage because the compressor in refrigerators (vapour compression refrigeration systems) needs fuel to work.The main problems brought in by the over use of fossil fuels are the quick depletion of fossil fuel resources and the environmental contamination.Therefore, a methodical approach is required to achieve the refrigeration system's optimized design parameters, which improve the refrigerator's overall functionality and reduce compressor work.Theoretical calculations can be used to create an optimized design, but they are subject to error because of the ambiguity and complexity when heat transmission from the refrigerant through the condenser tube towards the environment is formulated.To overcome this drawback, the problem is dealt practically.The project entails a trial run of an experimental vapour compression refrigeration system using various capillary tube sizes such as 0.031 in, 0.036 in and 0.042 in and refrigerator charges 100 g, 200 g and 300 g.Modification of Condenser & Evaporator coil subjected to forced convection is also incorporated.Investigation will be carried out for optimum geometry of capillary tube subjected to forced convection by regulating the condenser fan speed from 2 m/s to 3 m/s.Finally, the performance of the refrigeration system will be evaluated on different air velocities.And thus, it was found out that the unit working on the capillary tube of size 0.031in and refrigerant R134a had the maximum COP of 2.85, with refrigerant charge of 300 g at condenser fan speed of 3 m/s.

Authors

Institutions

Publication Details

Journal
International Journal of Heat and Technology
Published
2024-12-31
DOI
https://doi.org/10.18280/ijht.420605
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance of a VCR System with Variable Capillary Tube Geometry and R134a Refrigerant Charge Through Forced Convection at Various Air Velocities

Muhammad Basha, Mansour Al-Tuaysi, Eyad Al-Suhaibani, Naif Al-Mansoor
International Journal of Heat and Technology
Refrigeration and Air Conditioning Technologies
article

Performance of a VCR System with Variable Capillary Tube Geometry and R134a Refrigerant Charge Through Forced Convection at Various Air Velocities

Muhammad Basha, Mansour Al-Tuaysi, Eyad Al-Suhaibani, Naif Al-Mansoor
article en

Abstract

Refrigerators are now considered to be the most vital component of modern life.The primary criterion is energy usage because the compressor in refrigerators (vapour compression refrigeration systems) needs fuel to work.The main problems brought in by the over use of fossil fuels are the quick depletion of fossil fuel resources and the environmental contamination.Therefore, a methodical approach is required to achieve the refrigeration system's optimized design parameters, which improve the refrigerator's overall functionality and reduce compressor work.Theoretical calculations can be used to create an optimized design, but they are subject to error because of the ambiguity and complexity when heat transmission from the refrigerant through the condenser tube towards the environment is formulated.To overcome this drawback, the problem is dealt practically.The project entails a trial run of an experimental vapour compression refrigeration system using various capillary tube sizes such as 0.031 in, 0.036 in and 0.042 in and refrigerator charges 100 g, 200 g and 300 g.Modification of Condenser & Evaporator coil subjected to forced convection is also incorporated.Investigation will be carried out for optimum geometry of capillary tube subjected to forced convection by regulating the condenser fan speed from 2 m/s to 3 m/s.Finally, the performance of the refrigeration system will be evaluated on different air velocities.And thus, it was found out that the unit working on the capillary tube of size 0.031in and refrigerant R134a had the maximum COP of 2.85, with refrigerant charge of 300 g at condenser fan speed of 3 m/s.

International Journal of Heat and TechnologyVol. 42(6)
Qassim University (SA)
Affordable and clean energy
Openalex Percentile: Top 74%
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Performance of a VCR System with Variable Capillary Tube Geometry and R134a Refrigerant Charge Through Forced Convection at Various Air Velocities — Muhammad Basha, Mansour Al-Tuaysi, et al. · International Journal of Heat and Technology (2024) | TGRS Research Map | TGRS