Stability of dabigatran etexilate (Pradaxa) capsules in dose administration aids

Abstract Background Recent studies produced conflicting results on the suitability of repackaging dabigatran etexilate (Pradaxa) capsules in dose administration aids (DAAs). Aim To determine the stability of Pradaxa capsules in climate zones II (25°C and 60% relative humidity [RH]) and IVa (30°C and 65% RH). Method Pradaxa 110 mg capsules were subjected to two storage conditions (25°C/60% RH and 30°C/65% RH) in both the original packaging and after repackaging into Webster packs. Content assay, appearance, pH, and dissolution profile of capsules were determined at baseline, and 2 and 4 weeks after storage. Ethics approval was not required for this research article as it was a stability study and did not contain human participants or human data. Results Dabigatran etexilate content (± standard deviation) decreased significantly after 4 weeks of storage in DAAs at 30°C/65% RH (87.7% ± 4.4%). In addition, the amount of dabigatran etexilate released from the capsules at 45 min was significantly lower for capsules repackaged in DAAs and stored at 30°C/65% RH at both time points. Considerable changes in the appearance of capsule content were also observed following storage at 30°C/65% RH for 4 weeks in DAAs. There were no significant changes to dissolution profile or drug content of capsules repackaged and stored at 25°C/60% RH. No significant changes in the pH of dabigatran etexilate solutions were observed. Conclusion Repackaging impacts the chemical stability of dabigatran etexilate if the DAAs are exposed to climate zone IVa conditions. Although repackaged dabigatran etexilate stored at 25°C/60% RH appears to be stable, caution should be exercised if these DAAs are to be stored at ambient room conditions due to the inability to guarantee humidity levels.

Authors

Institutions

Publication Details

Journal
Journal of Pharmacy Practice and Research
Published
2025-01-16
DOI
https://doi.org/10.1002/jppr.1963
Primary Topic
Atrial Fibrillation Management and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Stability of dabigatran etexilate (Pradaxa) capsules in dose administration aids

Vivek B. Nooney, Thilini Rasika Thrimawithana, Alexandra M. E. Jones, Ayman Allahham et al.
Journal of Pharmacy Practice and Research
Atrial Fibrillation Management and Outcomes
article

Stability of dabigatran etexilate (Pradaxa) capsules in dose administration aids

Vivek B. Nooney, Thilini Rasika Thrimawithana, Alexandra M. E. Jones, Ayman Allahham, Brianna Jayne Weigl, Jyothsna Sridhar, Lama Farah
article en

Abstract

Abstract Background Recent studies produced conflicting results on the suitability of repackaging dabigatran etexilate (Pradaxa) capsules in dose administration aids (DAAs). Aim To determine the stability of Pradaxa capsules in climate zones II (25°C and 60% relative humidity [RH]) and IVa (30°C and 65% RH). Method Pradaxa 110 mg capsules were subjected to two storage conditions (25°C/60% RH and 30°C/65% RH) in both the original packaging and after repackaging into Webster packs. Content assay, appearance, pH, and dissolution profile of capsules were determined at baseline, and 2 and 4 weeks after storage. Ethics approval was not required for this research article as it was a stability study and did not contain human participants or human data. Results Dabigatran etexilate content (± standard deviation) decreased significantly after 4 weeks of storage in DAAs at 30°C/65% RH (87.7% ± 4.4%). In addition, the amount of dabigatran etexilate released from the capsules at 45 min was significantly lower for capsules repackaged in DAAs and stored at 30°C/65% RH at both time points. Considerable changes in the appearance of capsule content were also observed following storage at 30°C/65% RH for 4 weeks in DAAs. There were no significant changes to dissolution profile or drug content of capsules repackaged and stored at 25°C/60% RH. No significant changes in the pH of dabigatran etexilate solutions were observed. Conclusion Repackaging impacts the chemical stability of dabigatran etexilate if the DAAs are exposed to climate zone IVa conditions. Although repackaged dabigatran etexilate stored at 25°C/60% RH appears to be stable, caution should be exercised if these DAAs are to be stored at ambient room conditions due to the inability to guarantee humidity levels.

Journal of Pharmacy Practice and ResearchVol. 55(3)
RMIT University (AU)
Openalex Percentile: Top 99%
Atrial Fibrillation Management and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.