Characterization of bioaerosol exposures in wastewater treatment plant workers and serum levels of lung and inflammatory markers

Wastewater treatment plant (WWTP) workers are exposed to bioaerosols containing bacteria, fungi, and endotoxin, potentially posing health risks to workers. This study quantified personal exposure levels to airborne bacteria and fungi, endotoxin, and dust among 44 workers during two seasons at four WWTPs. Associations between the exposure measurements and serum levels of biomarkers CRP, SAA, and CC16 were also assessed. The potential deposition of viable microorganisms in workers' airways were explored using stationary fractionating samplers. Microbial communities were characterized using long-read nanopore amplicon sequencing and MALDI-TOF mass spectrometry to identify species, including pathogenic or allergenic microorganisms. We found that bacterial and fungal exposure levels were significantly associated with work task (p < 0.001 and p = 0.00041, respectively), with high exposure variability within and between tasks. Workshop, sewer system inspection, and sewer cleaning were associated with the highest exposure levels. A significant positive correlation was found between CRP and bacterial exposure (p = 0.013), while significant negative correlations were found between CRP and endotoxin and dust exposures (p = 0.012 and p = 0.018, respectively). No significant associations were found between SAA or CC16 and the exposure measures. Microbial community composition in bioaerosols differed significantly between some work tasks while others showed similar compositions. Viable hazardous microorganisms such as Clostridium perfringens and Aspergillus fumigatus were found in workers' exposures and in respiratory fractions of stationary air samples, indicating potential lung deposition. Further research is needed to assess possible long-term health risks from bioaerosol exposure at WWTPs.

Authors

Institutions

Publication Details

Journal
Journal of Hazardous Materials
Published
2025-01-16
DOI
https://doi.org/10.1016/j.jhazmat.2025.137254
Citations
3
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
3.60
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Characterization of bioaerosol exposures in wastewater treatment plant workers and serum levels of lung and inflammatory markers

Anne Mette Madsen, Jeppe Lund Nielsen, Pil Uthaug Rasmussen, Margit W. Frederiksen et al.
3 citations
Journal of Hazardous Materials
Indoor Air Quality and Microbial Exposure
3.60
article

Characterization of bioaerosol exposures in wastewater treatment plant workers and serum levels of lung and inflammatory markers

Anne Mette Madsen, Jeppe Lund Nielsen, Pil Uthaug Rasmussen, Margit W. Frederiksen, Stine Karstenskov Østergaard, Signe Agnete Møller
article en
3 citations

Abstract

Wastewater treatment plant (WWTP) workers are exposed to bioaerosols containing bacteria, fungi, and endotoxin, potentially posing health risks to workers. This study quantified personal exposure levels to airborne bacteria and fungi, endotoxin, and dust among 44 workers during two seasons at four WWTPs. Associations between the exposure measurements and serum levels of biomarkers CRP, SAA, and CC16 were also assessed. The potential deposition of viable microorganisms in workers' airways were explored using stationary fractionating samplers. Microbial communities were characterized using long-read nanopore amplicon sequencing and MALDI-TOF mass spectrometry to identify species, including pathogenic or allergenic microorganisms. We found that bacterial and fungal exposure levels were significantly associated with work task (p < 0.001 and p = 0.00041, respectively), with high exposure variability within and between tasks. Workshop, sewer system inspection, and sewer cleaning were associated with the highest exposure levels. A significant positive correlation was found between CRP and bacterial exposure (p = 0.013), while significant negative correlations were found between CRP and endotoxin and dust exposures (p = 0.012 and p = 0.018, respectively). No significant associations were found between SAA or CC16 and the exposure measures. Microbial community composition in bioaerosols differed significantly between some work tasks while others showed similar compositions. Viable hazardous microorganisms such as Clostridium perfringens and Aspergillus fumigatus were found in workers' exposures and in respiratory fractions of stationary air samples, indicating potential lung deposition. Further research is needed to assess possible long-term health risks from bioaerosol exposure at WWTPs.

Journal of Hazardous MaterialsVol. 487
National Research Centre for the Working Environment (DK), Aalborg University (DK)
Clean water and sanitation
Openalex Percentile: Top 10%
Indoor Air Quality and Microbial Exposure
3.60
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.