A control strategy for seismic noise reduction on advanced LIGO gravitational-wave detector

Abstract The differential seismic motion between the internal seismic isolation platforms on the advanced laser interferometer gravitational wave observatory, affects the sensitivity of the detector at lower frequencies (below 1 Hz), because each platform moves independently. This induces noise inside the cavities of the auxiliary optics placed on the platforms, which translates into a higher control effort to maintain stability and resonance. This paper shows that the differential motion between the platforms can be efficiently measured by the capacitive position sensors installed on each platform. We investigate how we can use these sensors to modify the seismic control configuration and help reduce the differential motion between the platforms, reduce the control efforts and help maintain the cavities in resonance. Reduced differential motion is expected to reduce control noise thereby improving sensitivity and improve detector duty cycle by preventing actuator saturation, resulting in loss of optical cavity resonance.

Authors

Institutions

Publication Details

Journal
Classical and Quantum Gravity
Published
2025-01-16
DOI
https://doi.org/10.1088/1361-6382/adab5f
Primary Topic
Seismic Waves and Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A control strategy for seismic noise reduction on advanced LIGO gravitational-wave detector

A. Pele, Sébastien Biscans, C. Di Fronzo, E. Schwartz et al.
Classical and Quantum Gravity
Seismic Waves and Analysis
article

A control strategy for seismic noise reduction on advanced LIGO gravitational-wave detector

A. Pele, Sébastien Biscans, C. Di Fronzo, E. Schwartz, B. Lantz, C. M. Mow‐Lowry, R. Mittleman, J. Warner, Jennifer C Driggers
article en

Abstract

Abstract The differential seismic motion between the internal seismic isolation platforms on the advanced laser interferometer gravitational wave observatory, affects the sensitivity of the detector at lower frequencies (below 1 Hz), because each platform moves independently. This induces noise inside the cavities of the auxiliary optics placed on the platforms, which translates into a higher control effort to maintain stability and resonance. This paper shows that the differential motion between the platforms can be efficiently measured by the capacitive position sensors installed on each platform. We investigate how we can use these sensors to modify the seismic control configuration and help reduce the differential motion between the platforms, reduce the control efforts and help maintain the cavities in resonance. Reduced differential motion is expected to reduce control noise thereby improving sensitivity and improve detector duty cycle by preventing actuator saturation, resulting in loss of optical cavity resonance.

Classical and Quantum GravityVol. 42(4)
The University of Western Australia (AU), LIGO Scientific Collaboration (US), College Summit (US), ARC Centre of Excellence for Gravitational Wave Discovery (AU), Massachusetts Institute of Technology (US), University of Birmingham (GB), Stanford University (US)
National Science Foundation, Directorate for STEM Education
Openalex Percentile: Top 99%
Seismic Waves and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.