Development of CPAP Overlay Interfaces for Efficient Administration of Aerosol Surfactant Therapy to Preterm Infants

The administration of surfactant aerosol therapy to preterm infants receiving continuous positive airway pressure (CPAP) respiratory support is highly challenging due to small flow passages, relatively high ventilation flow rates, rapid breathing and small inhalation volumes. To overcome these challenges, the objective of this study was to implement a validated computational fluid dynamics (CFD) model and develop an overlay nasal prong interface design for use with CPAP respiratory support that enables high efficiency powder aerosol delivery to the lungs of preterm infants when needed (i.e., on-demand) and can remain in place without increasing the work of breathing compared with a baseline CPAP interface. Realistic in vitro experiments were first conducted to generate baseline validation data, and then the CFD model, once validated, was used to explore key design parameters across a range of preterm infant nose-throat geometries and aerosol delivery conditions. The most important factors for efficient aerosol delivery were shown to be (i) maintaining the aerosol delivery flow rate below the tracheal flow rate (to minimize CPAP line loss) and (ii) concentrating the aerosol within the first portion of the inhalation waveform. An optimized design was shown to deliver approximately 37-60% of the nominal dose through the system and to the lungs with low intersubject variability (1050-2200 g infants) across two modes of device actuation (automated and manual) with room for further improvement. Ergonomic curvatures and streamlining of the prong geometries were also found to reduce work of breathing and flow resistance compared with a commercial alternative.

Authors

Institutions

Publication Details

Journal
AAPS PharmSciTech
Published
2025-01-16
DOI
https://doi.org/10.1208/s12249-024-02987-4
Citations
2
Primary Topic
Neonatal Respiratory Health Research
Type
article
Field-Weighted Citation Impact
3.04
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of CPAP Overlay Interfaces for Efficient Administration of Aerosol Surfactant Therapy to Preterm Infants

Dale Farkas, Michael Hindle, Sarah Strickler, P. Worth Longest et al.
2 citations
AAPS PharmSciTech
Neonatal Respiratory Health Research
3.04
article

Development of CPAP Overlay Interfaces for Efficient Administration of Aerosol Surfactant Therapy to Preterm Infants

Dale Farkas, Michael Hindle, Sarah Strickler, P. Worth Longest, Hasan Jubaer, Mohammad A. M. Momin, Kelley Melissa Dodson, Caleb Dalton
article en
2 citations

Abstract

The administration of surfactant aerosol therapy to preterm infants receiving continuous positive airway pressure (CPAP) respiratory support is highly challenging due to small flow passages, relatively high ventilation flow rates, rapid breathing and small inhalation volumes. To overcome these challenges, the objective of this study was to implement a validated computational fluid dynamics (CFD) model and develop an overlay nasal prong interface design for use with CPAP respiratory support that enables high efficiency powder aerosol delivery to the lungs of preterm infants when needed (i.e., on-demand) and can remain in place without increasing the work of breathing compared with a baseline CPAP interface. Realistic in vitro experiments were first conducted to generate baseline validation data, and then the CFD model, once validated, was used to explore key design parameters across a range of preterm infant nose-throat geometries and aerosol delivery conditions. The most important factors for efficient aerosol delivery were shown to be (i) maintaining the aerosol delivery flow rate below the tracheal flow rate (to minimize CPAP line loss) and (ii) concentrating the aerosol within the first portion of the inhalation waveform. An optimized design was shown to deliver approximately 37-60% of the nominal dose through the system and to the lungs with low intersubject variability (1050-2200 g infants) across two modes of device actuation (automated and manual) with room for further improvement. Ergonomic curvatures and streamlining of the prong geometries were also found to reduce work of breathing and flow resistance compared with a commercial alternative.

AAPS PharmSciTechVol. 26(1)
Virginia Commonwealth University (US)
Openalex Percentile: Top 11%
Neonatal Respiratory Health Research
3.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.