Non-invasive detection of urinary creatinine levels using a non-enzymatic electrochemical sensor with pectin-assisted Cu electrodeposition

A non-enzymatic electrochemical sensor prepared using Pectin-Cu-modified screen-printed carbon electrodes was utilized to detect creatinine levels in human urine. The sensor is highly reproducible, selective, and cost-effective, and it can be stably stored for a long period. • A highly reproducible and low-cost electrochemical sensor was developed. • The ion exchange between pectin and Cu 2+ assists in the uniform deposition of Cu. • This sensing is based on the formation of soluble Cu 2+ -creatinine complexes. • This sensor was successfully tested in diluted urine. • This sensor could be a tool to detect urinary creatinine in a clinical setting. Non-invasive creatinine monitoring is an attractive alternative to blood sampling for the assessment and management of chronic kidney disease. For this purpose, a non-enzymatic electrochemical sensor was introduced for non-invasive measurement of urinary creatinine levels. This sensor was prepared by utilizing ion exchange between pectin carboxyl groups and Cu 2+ to promote uniform deposition of Cu on screen-printed carbon electrode (denoted as Pectin-Cu/SPCE). This promising pectin-assisted Cu electrodeposition method prepares a sensor with a low detection limit of 9.6 µM for creatinine and a detection range of 20–1000 µM. Furthermore, the improved sensitivity of this sensor is attributed to the rapid movement of Cu 2+ and Cu 2+ -creatinine complexes on the electrode surface, which enhances the oxidation reaction. Also, this sensor demonstrates outstanding inter-batch reproducibility (n = 6) and good storage stability for 21 days. Moreover, this sensor can directly detect creatinine in diluted human urine without the need for complex pre-processing. The results were compared with the enzymatic method, and the accuracy was between 92.32 % and 97.87 %. As a result, this Pectin-Cu/SPCE-based non-enzymatic electrochemical sensor shows potential as a non-invasive urinary creatinine detection tool in a clinical setting.

Authors

Institutions

Publication Details

Journal
Microchemical Journal
Published
2025-01-16
DOI
https://doi.org/10.1016/j.microc.2025.112783
Citations
5
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
3.65
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Non-invasive detection of urinary creatinine levels using a non-enzymatic electrochemical sensor with pectin-assisted Cu electrodeposition

Hongming Hou, Futeng Li, Shuanglan Lin, Zhimin Li et al.
5 citations
Microchemical Journal
Electrochemical sensors and biosensors
3.65
article

Non-invasive detection of urinary creatinine levels using a non-enzymatic electrochemical sensor with pectin-assisted Cu electrodeposition

Hongming Hou, Futeng Li, Shuanglan Lin, Zhimin Li, Xianglong Li
article en
5 citations

Abstract

A non-enzymatic electrochemical sensor prepared using Pectin-Cu-modified screen-printed carbon electrodes was utilized to detect creatinine levels in human urine. The sensor is highly reproducible, selective, and cost-effective, and it can be stably stored for a long period. • A highly reproducible and low-cost electrochemical sensor was developed. • The ion exchange between pectin and Cu 2+ assists in the uniform deposition of Cu. • This sensing is based on the formation of soluble Cu 2+ -creatinine complexes. • This sensor was successfully tested in diluted urine. • This sensor could be a tool to detect urinary creatinine in a clinical setting. Non-invasive creatinine monitoring is an attractive alternative to blood sampling for the assessment and management of chronic kidney disease. For this purpose, a non-enzymatic electrochemical sensor was introduced for non-invasive measurement of urinary creatinine levels. This sensor was prepared by utilizing ion exchange between pectin carboxyl groups and Cu 2+ to promote uniform deposition of Cu on screen-printed carbon electrode (denoted as Pectin-Cu/SPCE). This promising pectin-assisted Cu electrodeposition method prepares a sensor with a low detection limit of 9.6 µM for creatinine and a detection range of 20–1000 µM. Furthermore, the improved sensitivity of this sensor is attributed to the rapid movement of Cu 2+ and Cu 2+ -creatinine complexes on the electrode surface, which enhances the oxidation reaction. Also, this sensor demonstrates outstanding inter-batch reproducibility (n = 6) and good storage stability for 21 days. Moreover, this sensor can directly detect creatinine in diluted human urine without the need for complex pre-processing. The results were compared with the enzymatic method, and the accuracy was between 92.32 % and 97.87 %. As a result, this Pectin-Cu/SPCE-based non-enzymatic electrochemical sensor shows potential as a non-invasive urinary creatinine detection tool in a clinical setting.

Microchemical JournalVol. 209
Sichuan University (CN), Chengdu University (CN), Science and Technology Department of Sichuan Province (CN)
Zero hunger
Openalex Percentile: Top 8%
Electrochemical sensors and biosensors
3.65
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.