Radon Re-entrainment Study—An Initial Investigation

Currently radon mitigation standards in United States residential homes and buildings require that the exhaust point for active fan-powered depressurization (ASD) systems exhaust be at or above the roofline of the building. There was very little evidence to support this requirement in the mid-1990s when the standards were published. This study was designed to examine the potential and safety of ground level exhaust. There are numerous advantages for ground level exhaust, such as aesthetics, safety, and reduced condensation, if properly placed along side of the building. A configurable exhaust point ASD design whereby we could change the exhaust from roofline to ground level was installed in 10 homes in the Harrisburg, PA, area. This design allowed us to change the configuration every 2 wk from roofline to ground level to baseline (off) conditions, with the house thereby acting as its own control, while extensively measuring the indoor and outdoor radon concentrations and other parameters over the course of 1 y. Over the year-long study, roofline and ground level exhaust configurations both showed very similar average indoor radon concentrations. Apart from the typical seasonal differences, there was little difference between average indoor radon levels for roof and ground level exhaust during each of the four seasons.

Authors

Institutions

Publication Details

Journal
Health Physics
Published
2025-01-16
DOI
https://doi.org/10.1097/hp.0000000000001941
Primary Topic
Wind and Air Flow Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Radon Re-entrainment Study—An Initial Investigation

Denise Bleiler, B.H. Turk, Robert K. Lewis, Richard C. Fox et al.
Health Physics
Wind and Air Flow Studies
article

Radon Re-entrainment Study—An Initial Investigation

Denise Bleiler, B.H. Turk, Robert K. Lewis, Richard C. Fox, Maria Coons, Jamie Ruminski
article en

Abstract

Currently radon mitigation standards in United States residential homes and buildings require that the exhaust point for active fan-powered depressurization (ASD) systems exhaust be at or above the roofline of the building. There was very little evidence to support this requirement in the mid-1990s when the standards were published. This study was designed to examine the potential and safety of ground level exhaust. There are numerous advantages for ground level exhaust, such as aesthetics, safety, and reduced condensation, if properly placed along side of the building. A configurable exhaust point ASD design whereby we could change the exhaust from roofline to ground level was installed in 10 homes in the Harrisburg, PA, area. This design allowed us to change the configuration every 2 wk from roofline to ground level to baseline (off) conditions, with the house thereby acting as its own control, while extensively measuring the indoor and outdoor radon concentrations and other parameters over the course of 1 y. Over the year-long study, roofline and ground level exhaust configurations both showed very similar average indoor radon concentrations. Apart from the typical seasonal differences, there was little difference between average indoor radon levels for roof and ground level exhaust during each of the four seasons.

Health PhysicsVol. 128(6)
Pennsylvania Department of Environmental Protection (US)
Sustainable cities and communities
Openalex Percentile: Top 99%
Wind and Air Flow Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Radon Re-entrainment Study—An Initial Investigation — Denise Bleiler, B.H. Turk, et al. · Health Physics (2025) | TGRS Research Map | TGRS