Optimization of Video Heart Rate Detection Based on Improved SSA Algorithm

A solution to address the issues of environmental light interference in Remote Photoplethysmography (rPPG) methods is proposed in this paper. First, signals from the face's region of interest (ROI) and background noise signals are simultaneously collected, and the two signals are processed by a differential to obtain a more accurate rPPG signal. This method effectively suppresses background noise and enhances signal quality. Secondly, the singular spectrum analysis algorithm (SSA) is enhanced to further improve the accuracy of heart rate detection. The algorithm's parameters are adaptively optimized by integrating the spectral and periodic characteristics of the heart rate signal. Experimental results demonstrate that the method proposed in this paper effectively mitigates the effects of lighting changes on heart rate detection, thereby enhancing detection accuracy. Overall, the experiments indicate that the proposed method significantly improves the effectiveness and accuracy of heart rate detection, achieving a high level of consistency with existing contact-based detection methods.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-01-16
DOI
https://doi.org/10.3390/s25020501
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization of Video Heart Rate Detection Based on Improved SSA Algorithm

Fei Dai, Xiangyang Liang, Chunmei Duan
Sensors
Non-Invasive Vital Sign Monitoring
article

Optimization of Video Heart Rate Detection Based on Improved SSA Algorithm

Fei Dai, Xiangyang Liang, Chunmei Duan
article en

Abstract

A solution to address the issues of environmental light interference in Remote Photoplethysmography (rPPG) methods is proposed in this paper. First, signals from the face's region of interest (ROI) and background noise signals are simultaneously collected, and the two signals are processed by a differential to obtain a more accurate rPPG signal. This method effectively suppresses background noise and enhances signal quality. Secondly, the singular spectrum analysis algorithm (SSA) is enhanced to further improve the accuracy of heart rate detection. The algorithm's parameters are adaptively optimized by integrating the spectral and periodic characteristics of the heart rate signal. Experimental results demonstrate that the method proposed in this paper effectively mitigates the effects of lighting changes on heart rate detection, thereby enhancing detection accuracy. Overall, the experiments indicate that the proposed method significantly improves the effectiveness and accuracy of heart rate detection, achieving a high level of consistency with existing contact-based detection methods.

SensorsVol. 25(2)
Xi'an Technological University (CN)
Openalex Percentile: Top 99%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.