Volt-VAr Management System

In this paper, the newly developed system has been integrated with auxiliary systems such as GIS (Geographic Information System), SCADA-DMS, and Field Device Controllers. It monitors the active and reactive power flow of feeders at TEİAŞ (Turkey's Electricity Transmission Corporation) transformer stations, while enabling the remote monitoring and automatic switching of reactors, capacitors, and MCR (Magnetic Controlled Reactors). Optimized reactive power and voltage management with the VVMS (Volt-VAr Management System) improves the power factor, reduces technical losses, and lowers energy costs. It also prevents low or high voltage issues through voltage regulation, thereby improving power quality. Additionally, reactive power management performs necessary calculations to ensure that inductive and capacitive limits are not exceeded, and the relevant equipment can be controlled remotely or via protection relays. The system aims to reduce energy losses and voltage drops, providing more efficient grid management.

Authors

Institutions

Publication Details

Journal
Orclever Proceedings of Research and Development
Published
2024-12-31
DOI
https://doi.org/10.56038/oprd.v5i1.547
Primary Topic
Industrial Automation and Control Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Volt-VAr Management System

Erman Terciyanlı, Zekeriya Güneş, Canan Şişman Korkmaz, Harun Köroğlu et al.
Orclever Proceedings of Research and Development
Industrial Automation and Control Systems
article

Volt-VAr Management System

Erman Terciyanlı, Zekeriya Güneş, Canan Şişman Korkmaz, Harun Köroğlu, Ayşegül Kutlay
article en

Abstract

In this paper, the newly developed system has been integrated with auxiliary systems such as GIS (Geographic Information System), SCADA-DMS, and Field Device Controllers. It monitors the active and reactive power flow of feeders at TEİAŞ (Turkey's Electricity Transmission Corporation) transformer stations, while enabling the remote monitoring and automatic switching of reactors, capacitors, and MCR (Magnetic Controlled Reactors). Optimized reactive power and voltage management with the VVMS (Volt-VAr Management System) improves the power factor, reduces technical losses, and lowers energy costs. It also prevents low or high voltage issues through voltage regulation, thereby improving power quality. Additionally, reactive power management performs necessary calculations to ensure that inductive and capacitive limits are not exceeded, and the relevant equipment can be controlled remotely or via protection relays. The system aims to reduce energy losses and voltage drops, providing more efficient grid management.

Orclever Proceedings of Research and DevelopmentVol. 5(1)
Navitas Systems (United States) (US)
Openalex Percentile: Top 69%
Industrial Automation and Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.