Four Quadrant Medium Voltage Drives

Medium voltage drives require regenerative capability for applications like lifts, conveyors with overhauling loads and other applications that require torque control or fast deceleration. One method to provide regeneration at low cost and low complexity in medium voltage drives is with the use of six-step control method. While the control of front-end semiconductor devices is simple, the resulting input currents have much higher distortion during regeneration as compared with the currents during motoring. During the last decade, the cascaded H-bridge (CHB) inverter has become the topology of choice for medium voltage (MV) motor drive applications. In this paper a CHB topology with low inverter count of nine is considered with six-step control. A new method to control the front-end devices of the individual inverters is proposed. Implementation of the method with a multi-pulse transformer is described. This method is shown, through simulations and circuit measurements, to improve the input current distortion of the input currents during regeneration while meeting the limits recommended in the IEEE-519 Standard.

Authors

Publication Details

Published
2024-09-16
DOI
https://doi.org/10.1109/pcic47799.2024.10832204
Primary Topic
Multilevel Inverters and Converters
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Four Quadrant Medium Voltage Drives

M. Rastogi, L. Mihalache
Multilevel Inverters and Converters
article

Four Quadrant Medium Voltage Drives

M. Rastogi, L. Mihalache
article en

Abstract

Medium voltage drives require regenerative capability for applications like lifts, conveyors with overhauling loads and other applications that require torque control or fast deceleration. One method to provide regeneration at low cost and low complexity in medium voltage drives is with the use of six-step control method. While the control of front-end semiconductor devices is simple, the resulting input currents have much higher distortion during regeneration as compared with the currents during motoring. During the last decade, the cascaded H-bridge (CHB) inverter has become the topology of choice for medium voltage (MV) motor drive applications. In this paper a CHB topology with low inverter count of nine is considered with six-step control. A new method to control the front-end devices of the individual inverters is proposed. Implementation of the method with a multi-pulse transformer is described. This method is shown, through simulations and circuit measurements, to improve the input current distortion of the input currents during regeneration while meeting the limits recommended in the IEEE-519 Standard.

Affordable and clean energy
Openalex Percentile: Top 76%
Multilevel Inverters and Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Four Quadrant Medium Voltage Drives — M. Rastogi, L. Mihalache · (2024) | TGRS Research Map | TGRS