Partial Discharge Diagnostics in Electric Motors Exposed to Ambient Stresses During Industrial Operations

In this paper the effect of contamination under varying temperature and relative humidity (RH) in electrical electric motors’ (EM) insulation is investigated through partial discharge (PD) diagnostics. The variations in PD intensity have been investigated under varying environmental conditions. For this purpose, PD measurements were carried out within an artificial industrial environment inside a climate-controlled chamber. Various PD features were extracted to study probability distribution functions to further investigate the PD severity at various levels of contamination, under varying temperatures and RH. Based on the experimental outcomes, it was revealed that PD activity within the EM insulation was significantly affected by temperature and RH under varying contamination conditions. The proposed methodology is believed to be helpful in achieving the desired level of reliability for a wide range of industrial applications exposed to ambient stresses.

Authors

Institutions

Publication Details

Published
2024-09-16
DOI
https://doi.org/10.1109/pcic47799.2024.10832267
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Partial Discharge Diagnostics in Electric Motors Exposed to Ambient Stresses During Industrial Operations

John Kay, Keyvan Firuzi, Azrul Mohd Ariffin, Ghulam Amjad Hussain et al.
High voltage insulation and dielectric phenomena
article

Partial Discharge Diagnostics in Electric Motors Exposed to Ambient Stresses During Industrial Operations

John Kay, Keyvan Firuzi, Azrul Mohd Ariffin, Ghulam Amjad Hussain, Waqar Hassan
article en

Abstract

In this paper the effect of contamination under varying temperature and relative humidity (RH) in electrical electric motors’ (EM) insulation is investigated through partial discharge (PD) diagnostics. The variations in PD intensity have been investigated under varying environmental conditions. For this purpose, PD measurements were carried out within an artificial industrial environment inside a climate-controlled chamber. Various PD features were extracted to study probability distribution functions to further investigate the PD severity at various levels of contamination, under varying temperatures and RH. Based on the experimental outcomes, it was revealed that PD activity within the EM insulation was significantly affected by temperature and RH under varying contamination conditions. The proposed methodology is believed to be helpful in achieving the desired level of reliability for a wide range of industrial applications exposed to ambient stresses.

University of Dubai (AE), Middle East Technical University (TR), Emmanuel Bible College (CA), Universiti Tenaga Nasional (MY)
Openalex Percentile: Top 83%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.