Indirect electrochemical detection of perfluoro decanoic acid from water

Electrochemical detection of perfluoro decanoic acid (PFDA) has gained significant interest due to the its environmental persistence and potential health risks. This study focuses on the development and utilization of a molecular imprinted polymer (MIP) sensor for the selective and sensitive detection of PFDA in aqueous samples. Commercial boron-doped diamond (BDD) electrode was modified with MIP by electro polymerization in 2:1 (v/v) mixture of 0.1 M sodium acetate buffer solution (pH = 5.8) and methanol containing 10 mM o-phenylenediamine (o-PD) and 1 mM PFDA concentration. The electro polymerization process was carried out using cyclic voltammetry (CV) by scanning 25 cyclic voltammograms in a potential range of 0.00 →1.00 V/SCE with a scan rate of 0.05 V·s-1. The electrochemical performance of the MIP-BDD sensor using cyclic voltammetry (CV), differential pulse voltammetry (DPV) and square wave voltammetry (SWV) was assessed. Considering both voltametric detections based on oxygen reduction reaction (ORR) and the lack of electrochemical activity of PFDA, investigation of its signal in the presence of increased PFDA concentrations is exploited for development of indirect detection method. Linear dependence between signal decrease vs. increasing PFDA concentrations allowed determining sensitivity and the lowest limit of detection of 0.160 nM (0.08 µg·dm-3) PFDA. The integration of MIP technology with electrochemical sensors offers a robust platform for environmental monitoring of PFDA, combining high selectivity, sensitivity and rapid response time. This method holds promise for advancing detection techniques for persistent organic pollutants in environmental and public health contexts.

Authors

Publication Details

Journal
Romanian Journal of Ecology & Environmental Chemistry
Published
2024-12-23
DOI
https://doi.org/10.21698/rjeec.2024.212
Primary Topic
Per- and polyfluoroalkyl substances research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Indirect electrochemical detection of perfluoro decanoic acid from water

Florica Manea, Sorina Motoc, Adina Păcală, Luoana Florentina Pascu et al.
Romanian Journal of Ecology & Environmental Chemistry
Per- and polyfluoroalkyl substances research
article

Indirect electrochemical detection of perfluoro decanoic acid from water

Florica Manea, Sorina Motoc, Adina Păcală, Luoana Florentina Pascu, Dorian Gabriel Neidoni, Anamaria Baciu, Sorina Negrea, Lidia Ani Diaconu, Elena Trif
article en

Abstract

Electrochemical detection of perfluoro decanoic acid (PFDA) has gained significant interest due to the its environmental persistence and potential health risks. This study focuses on the development and utilization of a molecular imprinted polymer (MIP) sensor for the selective and sensitive detection of PFDA in aqueous samples. Commercial boron-doped diamond (BDD) electrode was modified with MIP by electro polymerization in 2:1 (v/v) mixture of 0.1 M sodium acetate buffer solution (pH = 5.8) and methanol containing 10 mM o-phenylenediamine (o-PD) and 1 mM PFDA concentration. The electro polymerization process was carried out using cyclic voltammetry (CV) by scanning 25 cyclic voltammograms in a potential range of 0.00 →1.00 V/SCE with a scan rate of 0.05 V·s-1. The electrochemical performance of the MIP-BDD sensor using cyclic voltammetry (CV), differential pulse voltammetry (DPV) and square wave voltammetry (SWV) was assessed. Considering both voltametric detections based on oxygen reduction reaction (ORR) and the lack of electrochemical activity of PFDA, investigation of its signal in the presence of increased PFDA concentrations is exploited for development of indirect detection method. Linear dependence between signal decrease vs. increasing PFDA concentrations allowed determining sensitivity and the lowest limit of detection of 0.160 nM (0.08 µg·dm-3) PFDA. The integration of MIP technology with electrochemical sensors offers a robust platform for environmental monitoring of PFDA, combining high selectivity, sensitivity and rapid response time. This method holds promise for advancing detection techniques for persistent organic pollutants in environmental and public health contexts.

Romanian Journal of Ecology & Environmental ChemistryVol. 6(2)
Openalex Percentile: Top 80%
Per- and polyfluoroalkyl substances research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.