HIGH-SPEED OUTPUT STAGES OF OPERATIONAL AMPLIFIERS WITH DIFFERENCING CIRCUIT CORRECTION OF TRANSITION PROCESS
Further progress in microwave technology is inextricably linked with the creation of new precisionautomatic measuring systems. In our country, microwave circuit vector analyzers that can measure theamplitude and phase relationships of the S-parameters of the microwave networks under test are notmass-produced. The use of multi-port reflectometers (MPR) as measuring devices in automatic microwavecircuit analyzers allows creating relatively cheap and high-precision devices for studying load parameters.The paper provides an overview of the works in which the MPR method is developed, when the lattercan be represented by a multi-probe transmission line reflectometer (MTLR). The history of the developmentof measurement methods using traditional MPR is briefly described and it is shown that the mainproblem of their use is reflectometer calibration, which can be carried out accurately only using a set ofprecision calibration standards. MTLR, which is a special case of MPR, is studied in detail. It is shownthat random measurement errors by the MTLR method are higher than those of a precisely calibrated MR.However, the MTLR has important advantages that are discussed in the paper. A strategy for increasingthe measurement accuracy using the MTLR is described: 1) optimal methods for processing output signalsfrom the MTLR probes using the maximum likelihood method are proposed; 2) methods for calibrating the MTLR sensors are studied in detail and it is shown that it can be calibrated using a set of inaccurately knownloads with their parallel certification, therefore, systematic calibration errors are significantly reduced;3) methods for optimizing the MTLR design by arranging the probes inside the microwave path for measuringwith maximum accuracy in narrow and wide frequency ranges are studied, and it is also shown how it ispossible to measure with potentially achievable accuracy due to the proper choice of weighting coefficients inthe MTLR probes. Random and systematic errors in measuring the complex reflection index of microwaveloads, as well as uncertainties in measuring types A and B by the MTLR method are investigated, and referencesto relevant works are given. In conclusion, the possibilities of joint use of the MTLR and MPR methodsare considered, a combined MPR is briefly described, which measures with an accuracy characteristic of atraditional MPR, but can be calibrated using a set of unknown loads, which is inherent in the MTLR method.Automatic network analyzer, multi-pole reflectometer, multi-probe measuring line, maximum likelihoodmethod, error dispersion matrix, meter calibration.
Authors
- Alexey A. Zhuk (ORCID: https://orcid.org/0000-0002-7116-5924)
Publication Details
- Journal
- Izvestiâ ÛFU. Tehničeskie nauki
- Published
- 2024-11-13
- DOI
- https://doi.org/10.18522/2311-3103-2024-5-214-232
- Primary Topic
- Analog and Mixed-Signal Circuit Design
- Type
- article
- Field-Weighted Citation Impact
- 0.00