Abstract 273: Evaluating Clinical Outcomes and Cost‐Effectiveness of Robotic Carotid Artery Stenting: A Multi‐Center, Propensity Score Matched Study

Objective Preclinical studies suggest that robotic carotid artery stenting (CAS) could be superior to manual CAS. However, very limited comparative data exists comparing robotic and manual CAS patients. In addition, no data exists comparing the costs of manual and robotic CAS. Methods All robotic CAS cases at 2 academic neurosurgery centers were retrospectively reviewed and 1:1 propensity matched with manual CAS cases. Personnel costs, supply costs, and total procedure costs were collected in collaboration with hospital administration using time‐driven activity‐based cost‐analysis (TDABC). Results 24 robotic CAS cases were performed between 2019 and 2023. Co‐morbidities and baseline procedural characteristics were well‐matched between robotic and manual cases. Unplanned manual conversion was observed in only one robotic case (4.2%). Robotic CAS complications and outcomes were comparable to manual. Robotic CAS was associated with a significantly increased fluoroscopy time (29.0 vs. 19.2 min.; p<0.001). Robotic procedure time (88.9±18.2 min.) was significantly (p=0.003) higher than manual (68.72±22.4 min.). Health professional costs ($1,589.71±176.92, $1,375.99±233.39, p<0.005), supply cost ($3,918.25±421.20, $2,152.74±1,030.26, p<0.001) and total procedure costs ($5,306.11±608.95, $3,437.56±1,165.67, p<0.001) were greater for robotic CAS. Conclusions With a low rate of technical failure and post‐operative complications, we show robotic carotid artery stenting is safe and feasible in the first multi‐center and largest sample to date. In addition, robotic CAS achieves comparable clinical outcomes. Robotic CAS was associated with increased fluoroscopy time, but fluoroscopy time decreased as operators gained familiarity with the CorPath GRX. Robotic CAS was associated with a greater procedural cost, which was driven by greater personnel and supply costs. Our findings highlight the need for further studies to optimize robotic CAS and reduce its associated costs.

Authors

Institutions

Publication Details

Journal
Stroke Vascular and Interventional Neurology
Published
2024-11-01
DOI
https://doi.org/10.1161/svin.04.suppl_1.273
Primary Topic
Cerebrovascular and Carotid Artery Diseases
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 273: Evaluating Clinical Outcomes and Cost‐Effectiveness of Robotic Carotid Artery Stenting: A Multi‐Center, Propensity Score Matched Study

Antony A. Fuleihan, Joy Roy, Sheel Patel, Visish Mani Srinivasan et al.
Stroke Vascular and Interventional Neurology
Cerebrovascular and Carotid Artery Diseases
article

Abstract 273: Evaluating Clinical Outcomes and Cost‐Effectiveness of Robotic Carotid Artery Stenting: A Multi‐Center, Propensity Score Matched Study

Antony A. Fuleihan, Joy Roy, Sheel Patel, Visish Mani Srinivasan, Stavropoula I. Tjoumakaris, Kyle Scott, M Gooch, Robert H. Rossenwasser, Jan‐Karl Burkhardt, Basel Musmar, Advith Sarikonda, Ahilan Sivaganesan, Richat Abbas, Pascal Jabbour
article en

Abstract

Objective Preclinical studies suggest that robotic carotid artery stenting (CAS) could be superior to manual CAS. However, very limited comparative data exists comparing robotic and manual CAS patients. In addition, no data exists comparing the costs of manual and robotic CAS. Methods All robotic CAS cases at 2 academic neurosurgery centers were retrospectively reviewed and 1:1 propensity matched with manual CAS cases. Personnel costs, supply costs, and total procedure costs were collected in collaboration with hospital administration using time‐driven activity‐based cost‐analysis (TDABC). Results 24 robotic CAS cases were performed between 2019 and 2023. Co‐morbidities and baseline procedural characteristics were well‐matched between robotic and manual cases. Unplanned manual conversion was observed in only one robotic case (4.2%). Robotic CAS complications and outcomes were comparable to manual. Robotic CAS was associated with a significantly increased fluoroscopy time (29.0 vs. 19.2 min.; p<0.001). Robotic procedure time (88.9±18.2 min.) was significantly (p=0.003) higher than manual (68.72±22.4 min.). Health professional costs ($1,589.71±176.92, $1,375.99±233.39, p<0.005), supply cost ($3,918.25±421.20, $2,152.74±1,030.26, p<0.001) and total procedure costs ($5,306.11±608.95, $3,437.56±1,165.67, p<0.001) were greater for robotic CAS. Conclusions With a low rate of technical failure and post‐operative complications, we show robotic carotid artery stenting is safe and feasible in the first multi‐center and largest sample to date. In addition, robotic CAS achieves comparable clinical outcomes. Robotic CAS was associated with increased fluoroscopy time, but fluoroscopy time decreased as operators gained familiarity with the CorPath GRX. Robotic CAS was associated with a greater procedural cost, which was driven by greater personnel and supply costs. Our findings highlight the need for further studies to optimize robotic CAS and reduce its associated costs.

Stroke Vascular and Interventional NeurologyVol. 4(S1)
Thomas Jefferson University (US), WinnMed (US), California University of Pennsylvania (US), Sidney Kimmel Cancer Center (US), Mayo Clinic in Arizona (US), University of Pennsylvania (US)
Openalex Percentile: Top 56%
Cerebrovascular and Carotid Artery Diseases
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.