Abstract 403: Safety Profile of the Comaneci Device Across All Known Utilizations Worldwide

Comaneci (Rapid Medical, Yokneam, Israel) is the first adjustable remodeling device used for the treatment of wide necked aneurysms. The success and safety of Comaneci, combined with its ability to create adjustable radial force, has led to its more widespread use in the treatment of vasospasm. This specific use is enticing considering the rare but known risk of vessel rupture and death when using a balloon to treat vasospasm. If one could eliminate this risk and maintain efficacy, then the use of stents which exert adjustable radial force could supplant balloons for the mechanical treatment of vasospasm. Thus, we sought to investigate the safety of Comaneci across all known cases world wide.

Authors

Institutions

Publication Details

Journal
Stroke Vascular and Interventional Neurology
Published
2024-11-01
DOI
https://doi.org/10.1161/svin.04.suppl_1.403
Primary Topic
Quality and Safety in Healthcare
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 403: Safety Profile of the Comaneci Device Across All Known Utilizations Worldwide

Sean Scarpiello, Brian Thomas Jankowitz, Jari Haimi, Trevor A. Snyder et al.
Stroke Vascular and Interventional Neurology
Quality and Safety in Healthcare
article

Abstract 403: Safety Profile of the Comaneci Device Across All Known Utilizations Worldwide

Sean Scarpiello, Brian Thomas Jankowitz, Jari Haimi, Trevor A. Snyder, Haralabos Zacharatos
article en

Abstract

Comaneci (Rapid Medical, Yokneam, Israel) is the first adjustable remodeling device used for the treatment of wide necked aneurysms. The success and safety of Comaneci, combined with its ability to create adjustable radial force, has led to its more widespread use in the treatment of vasospasm. This specific use is enticing considering the rare but known risk of vessel rupture and death when using a balloon to treat vasospasm. If one could eliminate this risk and maintain efficacy, then the use of stents which exert adjustable radial force could supplant balloons for the mechanical treatment of vasospasm. Thus, we sought to investigate the safety of Comaneci across all known cases world wide.

Stroke Vascular and Interventional NeurologyVol. 4(S1)
University Medical Center (US), Hackensack Meridian Health (US)
Openalex Percentile: Top 46%
Quality and Safety in Healthcare
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.