Thermodynamic Analysis of Two-stage Vapour Compression Refrigeration Systems Using Eco-friendly Refrigerants

As Nigeria continues to expand its industrial, commercial, and residential cooling needs, the demand for efficient and environmentally sustainable refrigeration systems is growing. However, the environmental impact of conventional refrigerants has raised concerns due to their high global warming potential and ozone depletion potential. This study presents a thermodynamic analysis of two-stage vapour compression refrigeration systems in Nigeria, utilizing eco-friendly refrigerants which offer low global warming potential and zero ozone depletion potential. The refrigeration system comprises a high-pressure stage compressor and a low-pressure stage compressor with the inter stage pressure taken to be the ideal inter stage pressure. Performance analysis of R-717, R-600, R-600a and R-290 two-stage vapour compression refrigeration systems were made using seven parameters. The effect of the variation of five operating/design parameters (evaporating temperature, condensing temperature, superheating temperature, sub cooling temperature and refrigerant mass flow rate) on Coefficient of Performance (COP) of two-stage vapour compression system was analysed using engineering equation solver software. The results showed that as evaporating temperature decreases from 0oC to -50oC, COP decreased for all the four refrigerants considered. R-717 gave the highest COP value of 7.636 at evaporating temperature of 0oC while R-600a gave the lowest value of 4.009 at the same temperature. The results also showed that the COP of all the four refrigerants increased with increase in sub cooling temperature and Superheating Temperature, whereas it decreased with increase in condensing temperature. The study revealed that, except for the mass flow rate, all other operating parameters significantly affect the COP of refrigeration systems considered.

Authors

Institutions

Publication Details

Journal
Journal of Energy Research and Reviews
Published
2024-12-30
DOI
https://doi.org/10.9734/jenrr/2024/v16i12387
Citations
1
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thermodynamic Analysis of Two-stage Vapour Compression Refrigeration Systems Using Eco-friendly Refrigerants

A.A. Aderibigbe, Abiola J. Adeyi, Oladayo Adeyi, I. A. Babatunde et al.
1 citations
Journal of Energy Research and Reviews
Refrigeration and Air Conditioning Technologies
0.21
article

Thermodynamic Analysis of Two-stage Vapour Compression Refrigeration Systems Using Eco-friendly Refrigerants

A.A. Aderibigbe, Abiola J. Adeyi, Oladayo Adeyi, I. A. Babatunde, Akinola David Ogunsola, E.A. Fadiji, E.A. Owoo
article en
1 citations

Abstract

As Nigeria continues to expand its industrial, commercial, and residential cooling needs, the demand for efficient and environmentally sustainable refrigeration systems is growing. However, the environmental impact of conventional refrigerants has raised concerns due to their high global warming potential and ozone depletion potential. This study presents a thermodynamic analysis of two-stage vapour compression refrigeration systems in Nigeria, utilizing eco-friendly refrigerants which offer low global warming potential and zero ozone depletion potential. The refrigeration system comprises a high-pressure stage compressor and a low-pressure stage compressor with the inter stage pressure taken to be the ideal inter stage pressure. Performance analysis of R-717, R-600, R-600a and R-290 two-stage vapour compression refrigeration systems were made using seven parameters. The effect of the variation of five operating/design parameters (evaporating temperature, condensing temperature, superheating temperature, sub cooling temperature and refrigerant mass flow rate) on Coefficient of Performance (COP) of two-stage vapour compression system was analysed using engineering equation solver software. The results showed that as evaporating temperature decreases from 0oC to -50oC, COP decreased for all the four refrigerants considered. R-717 gave the highest COP value of 7.636 at evaporating temperature of 0oC while R-600a gave the lowest value of 4.009 at the same temperature. The results also showed that the COP of all the four refrigerants increased with increase in sub cooling temperature and Superheating Temperature, whereas it decreased with increase in condensing temperature. The study revealed that, except for the mass flow rate, all other operating parameters significantly affect the COP of refrigeration systems considered.

Journal of Energy Research and ReviewsVol. 16(12)
Ladoke Akintola University of Technology (NG)
Responsible consumption and production
Openalex Percentile: Top 48%
Refrigeration and Air Conditioning Technologies
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.