Identifying and mitigating resonance from a valve serving hibernaculum

This case study examines the challenges related to identifying and mitigating unwanted noise from a mechanical system serving hibernaculum, used for lemur torpor cycles. To support the torpor cycle, the design team determined a steady state background noise goal. Once installed, intermittent noise was discovered that the lemur research team felt might interfere with the rest cycle negatively affecting the lemurs and the results of any research. This presentation will review the investigation team’s methodology in identifying the main source of the noise, which was a coolant fluid value serving a fan powered box, review some of the measurement results, and discuss the solutions determined with the chamber design team. The implementation of the mitigation solution is underway and may be included in the presentation if completed by the time of presentation.

Authors

Publication Details

Journal
The Journal of the Acoustical Society of America
Published
2024-10-01
DOI
https://doi.org/10.1121/10.0035110
Primary Topic
Hydraulic and Pneumatic Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Identifying and mitigating resonance from a valve serving hibernaculum

Joseph F. Hackman, R. Bruce DeRoo
The Journal of the Acoustical Society of America
Hydraulic and Pneumatic Systems
article

Identifying and mitigating resonance from a valve serving hibernaculum

Joseph F. Hackman, R. Bruce DeRoo
article en

Abstract

This case study examines the challenges related to identifying and mitigating unwanted noise from a mechanical system serving hibernaculum, used for lemur torpor cycles. To support the torpor cycle, the design team determined a steady state background noise goal. Once installed, intermittent noise was discovered that the lemur research team felt might interfere with the rest cycle negatively affecting the lemurs and the results of any research. This presentation will review the investigation team’s methodology in identifying the main source of the noise, which was a coolant fluid value serving a fan powered box, review some of the measurement results, and discuss the solutions determined with the chamber design team. The implementation of the mitigation solution is underway and may be included in the presentation if completed by the time of presentation.

The Journal of the Acoustical Society of AmericaVol. 156(4_Supplement)
Openalex Percentile: Top 74%
Hydraulic and Pneumatic Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.