A Hybrid Method of SVG Parameter Calibration Based on Particle Swarm Optimization and Soft Actor-Critic

Static var generators (SVGS) are essential for compensating reactive power and maintaining bus voltage levels before and after large disturbances. Accurate modeling of SVG controller parameters is critical to ensure the reliability of dynamic simulation in power system operation. This paper introduces a novel SVG parameter identification method, which integrates the benefits of particle swarm optimization (PSO) and reinforcement learning (RL) to improve the efficiency and accuracy of parameter calibration. We use simulation data generated by PSD BPA software combined with actual power grid data as the environment to optimize the parameter settings of SVG. This study combined PSO with the Soft Actor-Critic (SAC) algorithm to optimize and calibrate these parameters. Compared with the simulation results, our method shows significant advantages in calibration accuracy and processing speed and effectively improves the simulation quality and practicability of the SVG model.

Authors

Institutions

Publication Details

Published
2024-08-15
DOI
https://doi.org/10.1109/prai62207.2024.10827804
Primary Topic
Fault Detection and Control Systems
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Hybrid Method of SVG Parameter Calibration Based on Particle Swarm Optimization and Soft Actor-Critic

Xuanchen Xiang, Hongyue Zhen, Ao Zhao, Guangjun Xu et al.
Fault Detection and Control Systems
article

A Hybrid Method of SVG Parameter Calibration Based on Particle Swarm Optimization and Soft Actor-Critic

Xuanchen Xiang, Hongyue Zhen, Ao Zhao, Guangjun Xu, Keqiang Yan, Ligang Zhao, Ruisheng Diao
article en

Abstract

Static var generators (SVGS) are essential for compensating reactive power and maintaining bus voltage levels before and after large disturbances. Accurate modeling of SVG controller parameters is critical to ensure the reliability of dynamic simulation in power system operation. This paper introduces a novel SVG parameter identification method, which integrates the benefits of particle swarm optimization (PSO) and reinforcement learning (RL) to improve the efficiency and accuracy of parameter calibration. We use simulation data generated by PSD BPA software combined with actual power grid data as the environment to optimize the parameter settings of SVG. This study combined PSO with the Soft Actor-Critic (SAC) algorithm to optimize and calibrate these parameters. Compared with the simulation results, our method shows significant advantages in calibration accuracy and processing speed and effectively improves the simulation quality and practicability of the SVG model.

Zhejiang University-University of Edinburgh Institute (CN), China Southern Power Grid (China) (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 69%
Fault Detection and Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.