Real-Time Wireless Centralized Control of the Level-Temperature Process in a Multipurpose Tank

In this work, a centralized MIMO (Multiple-Input Multiple-Output) integer-order control and a centralized MIMO fractional-order control, both wireless, are implemented in order to simultaneously control the water level and temperature of the upper tank in a multipurpose plant located in the Automation Laboratory of the University of Engineering and Technology (UTEC), in Peru. For the implementation of the wireless control systems, Siemens SCALANCE W774 and W734 devices were used, which operated with the Profinet communication protocol. The results obtained in the experiments demonstrate that the fractional-order centralized control approach exhibits better performance in level control compared to the integer-order centralized control approach, especially in terms of overshoot percentage and settling time. Regarding temperature control, the fractional-order centralized control approach shows a lower overshoot percentage and a lower steady-state error. However, in terms of settling time, the integer-order centralized control was better compared to its fractional counterpart.

Authors

Institutions

Publication Details

Published
2024-11-06
DOI
https://doi.org/10.1109/intercon63140.2024.10833495
Primary Topic
Advanced Algorithms and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Real-Time Wireless Centralized Control of the Level-Temperature Process in a Multipurpose Tank

Arturo Rojas–Moreno, Dante Inga Narváez, Callata Rosadio Ruben
Advanced Algorithms and Applications
article

Real-Time Wireless Centralized Control of the Level-Temperature Process in a Multipurpose Tank

Arturo Rojas–Moreno, Dante Inga Narváez, Callata Rosadio Ruben
article en

Abstract

In this work, a centralized MIMO (Multiple-Input Multiple-Output) integer-order control and a centralized MIMO fractional-order control, both wireless, are implemented in order to simultaneously control the water level and temperature of the upper tank in a multipurpose plant located in the Automation Laboratory of the University of Engineering and Technology (UTEC), in Peru. For the implementation of the wireless control systems, Siemens SCALANCE W774 and W734 devices were used, which operated with the Profinet communication protocol. The results obtained in the experiments demonstrate that the fractional-order centralized control approach exhibits better performance in level control compared to the integer-order centralized control approach, especially in terms of overshoot percentage and settling time. Regarding temperature control, the fractional-order centralized control approach shows a lower overshoot percentage and a lower steady-state error. However, in terms of settling time, the integer-order centralized control was better compared to its fractional counterpart.

Universidad de Ingeniería y Tecnología (PE)
Affordable and clean energy
Openalex Percentile: Top 69%
Advanced Algorithms and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Real-Time Wireless Centralized Control of the Level-Temperature Process in a Multipurpose Tank — Arturo Rojas–Moreno, Dante Inga Narváez, et al. · (2024) | TGRS Research Map | TGRS