Endoscopic Lesion Detection Based on Improved SSD

Aiming at the problem of low accuracy and speed of lesion detection by lightweight model, an endoscopic lesion detection algorithm based on improved SSD is proposed. Firstly, the VGG backbone network is replaced with a lighter MobileNetV2 network to reduce the consumption of computing resources. Secondly, the CBAM attention mechanism is proposed to refine the shallow input features, so as to comprehensively capture the key information of the features. Finally, the improved SmoothL1 loss function is used to balance the accuracy and robustness of the model. Experiments show that the average accuracy of the improved model is improved, the parameter amount is 1/6 of the original model, the calculation amount GFLOPS is reduced by 59 G, and the frame rate per second FPS is increased by 96 frames/s. Compared to other algorithms, there is an improvement in average accuracy, the model is more lightweight, and it consumes fewer computing resources, indicating the effectiveness of the improved algorithm in the detection of endoscopic lesions.

Authors

Institutions

Publication Details

Published
2024-10-25
DOI
https://doi.org/10.1109/rcae62637.2024.10834203
Primary Topic
Advanced Neural Network Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Endoscopic Lesion Detection Based on Improved SSD

Tao Wu, Ziqiang Shao, Lisheng Wei, Xiaohui Liu et al.
Advanced Neural Network Applications
article

Endoscopic Lesion Detection Based on Improved SSD

Tao Wu, Ziqiang Shao, Lisheng Wei, Xiaohui Liu, Xiaoxue Huang, Shengbo Zhu
article en

Abstract

Aiming at the problem of low accuracy and speed of lesion detection by lightweight model, an endoscopic lesion detection algorithm based on improved SSD is proposed. Firstly, the VGG backbone network is replaced with a lighter MobileNetV2 network to reduce the consumption of computing resources. Secondly, the CBAM attention mechanism is proposed to refine the shallow input features, so as to comprehensively capture the key information of the features. Finally, the improved SmoothL1 loss function is used to balance the accuracy and robustness of the model. Experiments show that the average accuracy of the improved model is improved, the parameter amount is 1/6 of the original model, the calculation amount GFLOPS is reduced by 59 G, and the frame rate per second FPS is increased by 96 frames/s. Compared to other algorithms, there is an improvement in average accuracy, the model is more lightweight, and it consumes fewer computing resources, indicating the effectiveness of the improved algorithm in the detection of endoscopic lesions.

Shanghai Jian Qiao University (CN), Anhui Polytechnic University (CN)
Openalex Percentile: Top 75%
Advanced Neural Network Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Endoscopic Lesion Detection Based on Improved SSD — Tao Wu, Ziqiang Shao, et al. · (2024) | TGRS Research Map | TGRS