Efficacy of Noninvasive Ventilation With Expiratory Washout in Stable COPD Patients

<b>Background:</b> A noninvasive ventilation (NIV) mask has been designed to deliver NIV with expiratory washout to improve efficacy of ventilation by optimizing clearance of expired gases from the anatomic dead space. This study compared the performance and comfort of a novel investigational mask with expiratory washout with a conventional mask during NIV therapy. <b>Methods:</b> In this pilot crossover study, participants with severe stable COPD attended a single visit to receive bi-level NIV through 2 masks; the investigational mask with expiratory washout and a conventional mask. The order of mask use was randomly allocated, and each mask was used for 60 min with a 30-60-min washout in between. The primary outcome was transcutaneous carbon dioxide at 60 min. Other physiologic and NIV device variables were also assessed. <b>Results:</b> The mean difference (95% CI) in the transcutaneous carbon dioxide between the investigational and conventional masks at 60 min, adjusted for baseline, was -0.74 mm Hg, 95% CI -2.81 to 1.33 mm Hg (<i>P</i> = .45). The investigational mask with expiratory washout elicited a lower tidal volume (-128.7 mL, 95% CI -190.0 to -67.3 mL; <i>P</i> < .001) and minute ventilation (-2.28 L/min,<sup>,</sup> 95% CI -3.12 to -1.43 L/min; <i>P</i> < .001), and a higher leak (7.96 L/min, 95% CI 4.39-11.54 L/min; <i>P</i> < .001) than the conventional mask. There were no differences in other physiologic responses or ratings of dyspnea or comfort. <b>Conclusions:</b> NIV therapy delivered by using a novel mask with expiratory washout was similarly effective at reducing transcutaneous carbon dioxide, whereas the delivered tidal volume and minute ventilation were significantly lower when compared with a conventional mask in participants with severe COPD.

Authors

Institutions

Publication Details

Journal
Respiratory Care
Published
2024-11-12
DOI
https://doi.org/10.1089/respcare.11876
Citations
2
Primary Topic
Respiratory Support and Mechanisms
Type
article
Field-Weighted Citation Impact
0.84
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Efficacy of Noninvasive Ventilation With Expiratory Washout in Stable COPD Patients

Sascha Zoellner, Louis Kirton, Richard Beasley, Ruth Semprini et al.
2 citations
Respiratory Care
Respiratory Support and Mechanisms
0.84
article

Efficacy of Noninvasive Ventilation With Expiratory Washout in Stable COPD Patients

Sascha Zoellner, Louis Kirton, Richard Beasley, Ruth Semprini, Allie Eathorne, Alex Semprini, Jess R. Fogarin, Stacey Kung
article en
2 citations

Abstract

<b>Background:</b> A noninvasive ventilation (NIV) mask has been designed to deliver NIV with expiratory washout to improve efficacy of ventilation by optimizing clearance of expired gases from the anatomic dead space. This study compared the performance and comfort of a novel investigational mask with expiratory washout with a conventional mask during NIV therapy. <b>Methods:</b> In this pilot crossover study, participants with severe stable COPD attended a single visit to receive bi-level NIV through 2 masks; the investigational mask with expiratory washout and a conventional mask. The order of mask use was randomly allocated, and each mask was used for 60 min with a 30-60-min washout in between. The primary outcome was transcutaneous carbon dioxide at 60 min. Other physiologic and NIV device variables were also assessed. <b>Results:</b> The mean difference (95% CI) in the transcutaneous carbon dioxide between the investigational and conventional masks at 60 min, adjusted for baseline, was -0.74 mm Hg, 95% CI -2.81 to 1.33 mm Hg (<i>P</i> = .45). The investigational mask with expiratory washout elicited a lower tidal volume (-128.7 mL, 95% CI -190.0 to -67.3 mL; <i>P</i> < .001) and minute ventilation (-2.28 L/min,<sup>,</sup> 95% CI -3.12 to -1.43 L/min; <i>P</i> < .001), and a higher leak (7.96 L/min, 95% CI 4.39-11.54 L/min; <i>P</i> < .001) than the conventional mask. There were no differences in other physiologic responses or ratings of dyspnea or comfort. <b>Conclusions:</b> NIV therapy delivered by using a novel mask with expiratory washout was similarly effective at reducing transcutaneous carbon dioxide, whereas the delivered tidal volume and minute ventilation were significantly lower when compared with a conventional mask in participants with severe COPD.

Respiratory CareVol. 70(1)
Medical Research Institute of New Zealand (NZ), Fisher & Paykel Healthcare (New Zealand) (NZ)
Zero hunger
Openalex Percentile: Top 22%
Respiratory Support and Mechanisms
0.84
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.