A Wearable System for Experimental Knee Pain During Real-World Locomotion: Habituation and Motor Adaptation

We developed a novel, wearable system that couples motion sensing and electrical stimulation in real-time to study motor adaptation in new environments. In two experiments we established key information needed in the development of our system including 1) pain habituation patterns and motor adaptations to knee pain while walking, 2) a model of electrical stimulation magnitude as a function of pain perception, and 3) gait-phase-dependent modulation of pain intensity. Over three 10-minute walking bouts, we observed significant pain habituation (p<0.001) to the tonic electrical stimuli after 60-210 seconds. However, by interleaving rest periods (10:10 min stimulation to rest), pain intensity returned to initial values at the start of the subsequent walking bouts (p=0.417, p=0.043). Participants also exhibited consistent local motor adaptation to the painful stimuli, consisting of greater knee flexion (1-3 degrees) throughout the gait cycle (sig. comparisons p<0.012) and across the walking bouts. We used the method of constants to quantify the pain intensity-stimulation magnitude relationship over 400 stimuli. A linear model fit the data well for intensities >1/10, though a piecewise linear (Adj R<sup>2</sup>=0.874) or exponential model (Adj R<sup>2</sup>=0.869) was required to fit the perception data across the stimulus intensity range (0-5/10). Finally, participants did not report gait-phase-dependent modulation of pain intensity while walking with tonic electrical stimulation. Our wearable system supports new motor adaptation experiments in novel contexts not previously possible. These results show the system induces localized pain perceptions and motor adaptations in complex movements (walking) while providing guidelines to structure future experimental pain studies.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Published
2025-01-01
DOI
https://doi.org/10.1109/tnsre.2025.3528910
Primary Topic
Musculoskeletal pain and rehabilitation
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Wearable System for Experimental Knee Pain During Real-World Locomotion: Habituation and Motor Adaptation

Liam H. Foulger, Jesse M. Charlton, Calvin Kuo, Jean‐Sébastien Blouin
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Musculoskeletal pain and rehabilitation
article

A Wearable System for Experimental Knee Pain During Real-World Locomotion: Habituation and Motor Adaptation

Liam H. Foulger, Jesse M. Charlton, Calvin Kuo, Jean‐Sébastien Blouin
article en

Abstract

We developed a novel, wearable system that couples motion sensing and electrical stimulation in real-time to study motor adaptation in new environments. In two experiments we established key information needed in the development of our system including 1) pain habituation patterns and motor adaptations to knee pain while walking, 2) a model of electrical stimulation magnitude as a function of pain perception, and 3) gait-phase-dependent modulation of pain intensity. Over three 10-minute walking bouts, we observed significant pain habituation (p<0.001) to the tonic electrical stimuli after 60-210 seconds. However, by interleaving rest periods (10:10 min stimulation to rest), pain intensity returned to initial values at the start of the subsequent walking bouts (p=0.417, p=0.043). Participants also exhibited consistent local motor adaptation to the painful stimuli, consisting of greater knee flexion (1-3 degrees) throughout the gait cycle (sig. comparisons p<0.012) and across the walking bouts. We used the method of constants to quantify the pain intensity-stimulation magnitude relationship over 400 stimuli. A linear model fit the data well for intensities >1/10, though a piecewise linear (Adj R<sup>2</sup>=0.874) or exponential model (Adj R<sup>2</sup>=0.869) was required to fit the perception data across the stimulus intensity range (0-5/10). Finally, participants did not report gait-phase-dependent modulation of pain intensity while walking with tonic electrical stimulation. Our wearable system supports new motor adaptation experiments in novel contexts not previously possible. These results show the system induces localized pain perceptions and motor adaptations in complex movements (walking) while providing guidelines to structure future experimental pain studies.

IEEE Transactions on Neural Systems and Rehabilitation EngineeringVol. 33
University of British Columbia (CA)
Natural Sciences and Engineering Research Council of Canada
Gender equality
Openalex Percentile: Top 99%
Musculoskeletal pain and rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.