A novel method utilizing a portable digital image-based colorimeter detector and a glutathione-functionalized gold nanoparticles (GSH-AuNPs) sensor for the highly selective and sensitive detection of creatinine in urine sample

Various methods can be employed to detect creatinine in urine, but the colorimetric method stands out for its speed, simplicity, and cost-effectiveness. In this study, glutathione-functionalized gold nanoparticles (GSH-AuNPs) were synthesized and used as a sensor to detect creatinine, utilizing a portable digital image-based colorimeter developed in our laboratory. The synthesized GSH-AuNPs exhibit a distinctive wine-red colour and have a uniform spherical shape with an average size of 56.7 nm, showing a maximum absorbance peak at a wavelength of 522 nm. The optimum conditions for detecting creatinine were a pH of 6 and a reaction time of 20 min. FTIR data confirm that the detection mechanism involves hydrogen bond between the -NH 2 group of creatinine and the -COO - group on the surface of the GSH-AuNPs. This is evidenced by a shift in the stretching vibration of the -COO - , leading to the aggregation of the GSH-AuNPs, resulting in an average size of 191.5 nm. The developed portable colorimeter, used as a detector for the GSH-AuNPs sensor in creatinine detection, achieved a limit of detection (LoD) of 0.016 mM. In comparison, the UV–Vis spectrophotometer as the detector has a LoD of 0.029 mM, and the Jaffe method has a LoD of 0.038 mM, making the proposed colorimetric method the most sensitive. The proposed colorimetric method demonstrates good selectivity for creatinine and has been successfully applied to detect creatinine in artificial urine with a recovery value of 99–103 %. • Several methods for determining creatinine face challenges like being time-consuming, complex prep, & needing skilled techs. • We developed a new colorimetric method for creatinine using GSH-AuNPs as sensors, detected with digital image colorimeter. • This combination shortens analysis time increases sensitivity, selectivity, and portability compared to existing methods. • The method accurately determines creatinine in human urine and encourages further exploration for use in medical samples.

Authors

Institutions

Publication Details

Journal
Sensors International
Published
2025-01-01
DOI
https://doi.org/10.1016/j.sintl.2025.100327
Citations
4
Primary Topic
Advanced Nanomaterials in Catalysis
Type
article
Field-Weighted Citation Impact
2.07

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A novel method utilizing a portable digital image-based colorimeter detector and a glutathione-functionalized gold nanoparticles (GSH-AuNPs) sensor for the highly selective and sensitive detection of creatinine in urine sample

Eduwin Saputra, Fajar Inggit Pambudi, Sri Juari Santosa, Alimin et al.
4 citations
Sensors International
Advanced Nanomaterials in Catalysis
2.07
article

A novel method utilizing a portable digital image-based colorimeter detector and a glutathione-functionalized gold nanoparticles (GSH-AuNPs) sensor for the highly selective and sensitive detection of creatinine in urine sample

Eduwin Saputra, Fajar Inggit Pambudi, Sri Juari Santosa, Alimin, Zora Rispa Kase, Idham Ananta Timur, Aufaclav Zatu Kusuma Frisky, Naufal Dhaffa Akbar Wicaksono, Wisnu Aryo Jatmiko, Zulfa Munawwaroh
article en
4 citations

Abstract

Various methods can be employed to detect creatinine in urine, but the colorimetric method stands out for its speed, simplicity, and cost-effectiveness. In this study, glutathione-functionalized gold nanoparticles (GSH-AuNPs) were synthesized and used as a sensor to detect creatinine, utilizing a portable digital image-based colorimeter developed in our laboratory. The synthesized GSH-AuNPs exhibit a distinctive wine-red colour and have a uniform spherical shape with an average size of 56.7 nm, showing a maximum absorbance peak at a wavelength of 522 nm. The optimum conditions for detecting creatinine were a pH of 6 and a reaction time of 20 min. FTIR data confirm that the detection mechanism involves hydrogen bond between the -NH 2 group of creatinine and the -COO - group on the surface of the GSH-AuNPs. This is evidenced by a shift in the stretching vibration of the -COO - , leading to the aggregation of the GSH-AuNPs, resulting in an average size of 191.5 nm. The developed portable colorimeter, used as a detector for the GSH-AuNPs sensor in creatinine detection, achieved a limit of detection (LoD) of 0.016 mM. In comparison, the UV–Vis spectrophotometer as the detector has a LoD of 0.029 mM, and the Jaffe method has a LoD of 0.038 mM, making the proposed colorimetric method the most sensitive. The proposed colorimetric method demonstrates good selectivity for creatinine and has been successfully applied to detect creatinine in artificial urine with a recovery value of 99–103 %. • Several methods for determining creatinine face challenges like being time-consuming, complex prep, & needing skilled techs. • We developed a new colorimetric method for creatinine using GSH-AuNPs as sensors, detected with digital image colorimeter. • This combination shortens analysis time increases sensitivity, selectivity, and portability compared to existing methods. • The method accurately determines creatinine in human urine and encourages further exploration for use in medical samples.

Sensors InternationalVol. 6
Universitas Gadjah Mada (ID), Universitas Halu Oleo (ID)
Universitas Gadjah Mada
Openalex Percentile: Top 15%
Advanced Nanomaterials in Catalysis
2.07
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines