An Adaptive Optimal Excitation Signal Control Method for Forced Oscillation Technique-Based Respiratory Impedance Measurement System

Nowadays the forced oscillation technique (FOT) for respiratory impedance measurement is increasingly used in clinical settings due to its simplicity, but current multifrequency measurement systems are unable to autonomously adjust the measurement frequency combinations based on clinical requirements, nor can they adaptively output the optimal excitation signals for different frequency combinations, limiting both flexibility and measurement quality. This study established a model for the FOT measurement system and analyzed the time-frequency domain response using Fourier analysis. Based on clinical studies of the FOT excitation signal, we first proposed a phase-genetic algorithm to search for the optimal phase combination that minimizes the peak-to-peak amplitude of pseudo-random signals, providing a phase reference for the control of the excitation signal. Then we proposed an optimal excitation signal control method based on the principle of linear superposition of signals and the concept of closed-loop control, which does not require specific model parameters of the system. It performs zero-phase initial superposition of signals with arbitrary frequency combinations to drive the loudspeaker and generate an output excitation signal. The excitation signal is sampled, decomposed, and estimated in the time-frequency domain to adjust the amplitude and phase of different frequency components of the drive signal, achieving optimal output for the measurement excitation signal. This method is highly adaptive to different input frequency combinations and system parameters. Experiments with various loudspeaker sizes and test frequencies verified the method’s feasibility and applicability, showing significant improvements in detection accuracy and repeatability.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3529063
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Adaptive Optimal Excitation Signal Control Method for Forced Oscillation Technique-Based Respiratory Impedance Measurement System

Fengwei Chen, Zhihui Wang, Rui Wang, Guo Yang et al.
IEEE Transactions on Instrumentation and Measurement
Non-Invasive Vital Sign Monitoring
article

An Adaptive Optimal Excitation Signal Control Method for Forced Oscillation Technique-Based Respiratory Impedance Measurement System

Fengwei Chen, Zhihui Wang, Rui Wang, Guo Yang, Xin Yang
article en

Abstract

Nowadays the forced oscillation technique (FOT) for respiratory impedance measurement is increasingly used in clinical settings due to its simplicity, but current multifrequency measurement systems are unable to autonomously adjust the measurement frequency combinations based on clinical requirements, nor can they adaptively output the optimal excitation signals for different frequency combinations, limiting both flexibility and measurement quality. This study established a model for the FOT measurement system and analyzed the time-frequency domain response using Fourier analysis. Based on clinical studies of the FOT excitation signal, we first proposed a phase-genetic algorithm to search for the optimal phase combination that minimizes the peak-to-peak amplitude of pseudo-random signals, providing a phase reference for the control of the excitation signal. Then we proposed an optimal excitation signal control method based on the principle of linear superposition of signals and the concept of closed-loop control, which does not require specific model parameters of the system. It performs zero-phase initial superposition of signals with arbitrary frequency combinations to drive the loudspeaker and generate an output excitation signal. The excitation signal is sampled, decomposed, and estimated in the time-frequency domain to adjust the amplitude and phase of different frequency components of the drive signal, achieving optimal output for the measurement excitation signal. This method is highly adaptive to different input frequency combinations and system parameters. Experiments with various loudspeaker sizes and test frequencies verified the method’s feasibility and applicability, showing significant improvements in detection accuracy and repeatability.

IEEE Transactions on Instrumentation and MeasurementVol. 74
Chongqing University (CN)
Openalex Percentile: Top 100%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.