Three-Dimensional Electrical Impedance Imaging During Spontaneous Breathing Trials in Patients With Acute Hypoxic Respiratory Failure: A Pilot Study

The purpose of this work is to evaluate the feasibility of lung imaging using 3D electrical impedance tomography (EIT) during spontaneous breathing trials (SBTs) in patients with acute hypoxic respiratory failure. EIT is a noninvasive, nonionizing, real-time functional imaging technique, suitable for bedside monitoring in critically ill patients. EIT data were collected in 24 mechanically ventilated patients immediately preceding and during a SBT on two rows of 16 electrodes using a simultaneous multicurrent source EIT system for 3D imaging. Dynamic 3D EIT images of conductivity were computed, as well as the EIT-derived rapid shallow breathing index, regional ventilation delay, global inhomogeneity index, and time traces of tidal volumes. 3D reconstructions and derived measures demonstrated inhomogeneity in ventilation distribution within patients. We conclude that 3D EIT images can provide information regarding ventilatory heterogeneity across the lung and may be useful in guiding ventilator management.

Authors

Institutions

Publication Details

Journal
Critical Care Explorations
Published
2025-01-01
DOI
https://doi.org/10.1097/cce.0000000000001198
Citations
4
Primary Topic
Electrical and Bioimpedance Tomography
Type
article
Field-Weighted Citation Impact
2.92
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Three-Dimensional Electrical Impedance Imaging During Spontaneous Breathing Trials in Patients With Acute Hypoxic Respiratory Failure: A Pilot Study

Jennifer L. Mueller, Nilton Barbosa da Rosa, Ellen Lyda Burnham, Tzu‐Jen Kao et al.
4 citations
Critical Care Explorations
Electrical and Bioimpedance Tomography
2.92
article

Three-Dimensional Electrical Impedance Imaging During Spontaneous Breathing Trials in Patients With Acute Hypoxic Respiratory Failure: A Pilot Study

Jennifer L. Mueller, Nilton Barbosa da Rosa, Ellen Lyda Burnham, Tzu‐Jen Kao, J. Brinton, Patrick J. Offner
article en
4 citations

Abstract

The purpose of this work is to evaluate the feasibility of lung imaging using 3D electrical impedance tomography (EIT) during spontaneous breathing trials (SBTs) in patients with acute hypoxic respiratory failure. EIT is a noninvasive, nonionizing, real-time functional imaging technique, suitable for bedside monitoring in critically ill patients. EIT data were collected in 24 mechanically ventilated patients immediately preceding and during a SBT on two rows of 16 electrodes using a simultaneous multicurrent source EIT system for 3D imaging. Dynamic 3D EIT images of conductivity were computed, as well as the EIT-derived rapid shallow breathing index, regional ventilation delay, global inhomogeneity index, and time traces of tidal volumes. 3D reconstructions and derived measures demonstrated inhomogeneity in ventilation distribution within patients. We conclude that 3D EIT images can provide information regarding ventilatory heterogeneity across the lung and may be useful in guiding ventilator management.

Critical Care ExplorationsVol. 7(1)
GE Global Research (United States) (US), University of Colorado Anschutz Medical Campus (US), University of Colorado Denver (US), Colorado State University (US)
Openalex Percentile: Top 10%
Electrical and Bioimpedance Tomography
2.92
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.