ESP32 and MAX30100 with Chebyshev Filter for Enhanced Heart and Oxygen Measurement

Health monitoring is important in the technology and information era. A health monitoring device must possess high accuracy in monitoring an individual's health. The MAX30100 sensor still exhibits low accuracy and requires improvements to enhance its precision. This study proposes a remote health monitoring system based on a MAX30100 sensor for heart rate and oxygen saturation detection. The digital signal processing method uses the Chebyshev II filter on PPG to reduce noise, and the RSA algorithm is employed to enhance data security. The results of testing the MAX30100 sensor value without a filter produced the lowest error value of 0.97%, the highest 6.59% for BPM, the lowest error value of 1.88%, and the highest error of 2.66% for SpO2. The MAX30100 sensor with the Chebyshev II filter that the author proposed has the highest level of accuracy with a low error value compared to previous tests, with the lowest error value of 0.23% and the highest 0.99% for BPM and the lowest error value of 0% and the highest error of 0.2% for SpO2. The RSA algorithm ensures secure data transmission from data modification by eavesdroppers. The average total time required by the system is 542.9 ms.

Authors

Publication Details

Journal
Jurnal RESTI (Rekayasa Sistem dan Teknologi Informasi)
Published
2024-10-19
DOI
https://doi.org/10.29207/resti.v8i5.5945
Citations
2
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.37
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ESP32 and MAX30100 with Chebyshev Filter for Enhanced Heart and Oxygen Measurement

Magfirawaty Magfirawaty, Naval Indra Waskita, Hizkia Menahem Tandungan, Ridhan Hafizh et al.
2 citations
Jurnal RESTI (Rekayasa Sistem dan Teknologi Informasi)
Non-Invasive Vital Sign Monitoring
0.37
article

ESP32 and MAX30100 with Chebyshev Filter for Enhanced Heart and Oxygen Measurement

Magfirawaty Magfirawaty, Naval Indra Waskita, Hizkia Menahem Tandungan, Ridhan Hafizh, Syifa Jauza Suwaendi
article en
2 citations

Abstract

Health monitoring is important in the technology and information era. A health monitoring device must possess high accuracy in monitoring an individual's health. The MAX30100 sensor still exhibits low accuracy and requires improvements to enhance its precision. This study proposes a remote health monitoring system based on a MAX30100 sensor for heart rate and oxygen saturation detection. The digital signal processing method uses the Chebyshev II filter on PPG to reduce noise, and the RSA algorithm is employed to enhance data security. The results of testing the MAX30100 sensor value without a filter produced the lowest error value of 0.97%, the highest 6.59% for BPM, the lowest error value of 1.88%, and the highest error of 2.66% for SpO2. The MAX30100 sensor with the Chebyshev II filter that the author proposed has the highest level of accuracy with a low error value compared to previous tests, with the lowest error value of 0.23% and the highest 0.99% for BPM and the lowest error value of 0% and the highest error of 0.2% for SpO2. The RSA algorithm ensures secure data transmission from data modification by eavesdroppers. The average total time required by the system is 542.9 ms.

Jurnal RESTI (Rekayasa Sistem dan Teknologi Informasi)Vol. 8(5)
Openalex Percentile: Top 41%
Non-Invasive Vital Sign Monitoring
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

ESP32 and MAX30100 with Chebyshev Filter for Enhanced Heart and Oxygen Measurement — Magfirawaty Magfirawaty, Naval Indra Waskita, et al. · Jurnal RESTI (Rekayasa Sistem dan Teknologi Informasi) (2024) | TGRS Research Map | TGRS