Novel RP-HPLC Method Development and Validation of Budesonide Suppository

In the current study, a simple and cost-effective stability-indicating RP-HPLC method was developed and validated to estimate Budesonide from bulk and pharmaceutical dosage forms.0.1% formic acid and methanol (15:85 v/v) were employed as the mobile phase with an injection volume of 20μl, and detection was carried out at 244 nm. The developed method was validated as per ICH Q2 guidelines. The RT of Budesonide was determined to be 4.3 ± 0.328 minutes, providing a reliable marker for its identification. The method was found to be linear between 2-12 μg/ml concentration with (R²) of 0.997. This demonstrates the method's ability to measure varying concentrations of Budesonide accurately. Additionally, the percentage recovery of Budesonide was approximately 100%, confirming the accuracy of the developed method. The parameters for the system's suitability have also been found to be within acceptable limits. Force degradation studies reinforced the method's selectivity and sensitivity in detecting Budesonide under various degradation scenarios. In conclusion, our proposed RP-HPLC method provides a sensitive, accurate, and precise way to analyze Budesonide in bulk and pharmaceutical dosage forms.

Publication Details

Journal
Letters in Applied NanoBioScience
Published
2024-12-30
DOI
https://doi.org/10.33263/lianbs134.196
Primary Topic
Microscopic Colitis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Novel RP-HPLC Method Development and Validation of Budesonide Suppository

Letters in Applied NanoBioScience
Microscopic Colitis
article

Novel RP-HPLC Method Development and Validation of Budesonide Suppository

article en

Abstract

In the current study, a simple and cost-effective stability-indicating RP-HPLC method was developed and validated to estimate Budesonide from bulk and pharmaceutical dosage forms.0.1% formic acid and methanol (15:85 v/v) were employed as the mobile phase with an injection volume of 20μl, and detection was carried out at 244 nm. The developed method was validated as per ICH Q2 guidelines. The RT of Budesonide was determined to be 4.3 ± 0.328 minutes, providing a reliable marker for its identification. The method was found to be linear between 2-12 μg/ml concentration with (R²) of 0.997. This demonstrates the method's ability to measure varying concentrations of Budesonide accurately. Additionally, the percentage recovery of Budesonide was approximately 100%, confirming the accuracy of the developed method. The parameters for the system's suitability have also been found to be within acceptable limits. Force degradation studies reinforced the method's selectivity and sensitivity in detecting Budesonide under various degradation scenarios. In conclusion, our proposed RP-HPLC method provides a sensitive, accurate, and precise way to analyze Budesonide in bulk and pharmaceutical dosage forms.

Letters in Applied NanoBioScienceVol. 13(4)
Savitribai Phule Pune University
Openalex Percentile: Top 63%
Microscopic Colitis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.