Regression Model Analysis of Mandibular Locator CAD/CAM-Milled Bar Implant Overdenture: Bio-simulation Finite Element Study

Objective: To compare the performances of various materials used in mandibular locator CAD/CAM-milled bar implant overdentures based on biomechanics using finite element analysis and regression modeling.Materials and Methods: Four materials were analyzed, Titanium Alloy Type IV, Polyether Ether Ketone (PEEK), Cobalt Chromium Alloy Type III, and High Strength Zirconia. A 3D model of an edentulous mandible with four implants was created with Solidworks software. FEA was run to determine von Mises stress, resultant displacement, and equivalent strain using static load study under applied loads from 0 to 200 N. Linear regression analysis was performed to build models to predict equivalent strain.Results: Maximum resultant displacement and equivalent strain were shown by the PEEK followed by Titanium Alloy Type IV, Cobalt Chromium Alloy Type III, and High Strength Zirconia. Regression analysis showed an excellent linear relationship for all the materials. Thus, regression values can be used to predict equivalent strain.Conclusion: Material choices greatly affect stress distribution and deformation within implant-supported restorations. While PEEK was more deformable, it may have produced the highest stress on the prosthetic components. Titanium Alloy Type IV and Cobalt Chromium Alloy Type III had the most similar patterns of stress in the supporting bone. High Strength Zirconia demonstrated the least stress on implant assemblies compared to titanium.

Authors

Institutions

Publication Details

Journal
Egyptian Dental Journal /Egyptian Dental Journal
Published
2025-01-01
DOI
https://doi.org/10.21608/edj.2024.297791.3082
Citations
1
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
1.79
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Regression Model Analysis of Mandibular Locator CAD/CAM-Milled Bar Implant Overdenture: Bio-simulation Finite Element Study

Sherihan M. Eissa, Shady M. EL Naggar
1 citations
Egyptian Dental Journal /Egyptian Dental Journal
Dental Implant Techniques and Outcomes
1.79
article

Regression Model Analysis of Mandibular Locator CAD/CAM-Milled Bar Implant Overdenture: Bio-simulation Finite Element Study

Sherihan M. Eissa, Shady M. EL Naggar
article en
1 citations

Abstract

Objective: To compare the performances of various materials used in mandibular locator CAD/CAM-milled bar implant overdentures based on biomechanics using finite element analysis and regression modeling.Materials and Methods: Four materials were analyzed, Titanium Alloy Type IV, Polyether Ether Ketone (PEEK), Cobalt Chromium Alloy Type III, and High Strength Zirconia. A 3D model of an edentulous mandible with four implants was created with Solidworks software. FEA was run to determine von Mises stress, resultant displacement, and equivalent strain using static load study under applied loads from 0 to 200 N. Linear regression analysis was performed to build models to predict equivalent strain.Results: Maximum resultant displacement and equivalent strain were shown by the PEEK followed by Titanium Alloy Type IV, Cobalt Chromium Alloy Type III, and High Strength Zirconia. Regression analysis showed an excellent linear relationship for all the materials. Thus, regression values can be used to predict equivalent strain.Conclusion: Material choices greatly affect stress distribution and deformation within implant-supported restorations. While PEEK was more deformable, it may have produced the highest stress on the prosthetic components. Titanium Alloy Type IV and Cobalt Chromium Alloy Type III had the most similar patterns of stress in the supporting bone. High Strength Zirconia demonstrated the least stress on implant assemblies compared to titanium.

Egyptian Dental Journal /Egyptian Dental JournalVol. 71(1)
Benha University (EG), National Research Centre (EG), Universitas 17 Agustus 1945 Semarang (ID)
Climate action
Openalex Percentile: Top 21%
Dental Implant Techniques and Outcomes
1.79
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Regression Model Analysis of Mandibular Locator CAD/CAM-Milled Bar Implant Overdenture: Bio-simulation Finite Element Study — Sherihan M. Eissa, Shady M. EL Naggar · Egyptian Dental Journal /Egyptian Dental Journal (2025) | TGRS Research Map | TGRS