Accuracy of Digital Impressions Obtained by Different Intraoral Scanners Compared with The Laboratory Scanner for Implants Placed in Partially Edentulous Mandible: An In Vitro Study.

Aim: The aim of this in vitro study was to evaluate the accuracy of three different intraoral scanners (Medit i700, 3Shape TRIOS 4 and Carestream CS3600) versus the desktop lab scanner for implants placed in Kennedy class II partially edentulous mandible.Methodology: A 3D-printed resin cast simulating a Kennedy Class II mandibular arch with two implants, in the first premolar and first molar regions, was used. Each scan body and the mucosal part of the edentulous area were scanned once by a laboratory scanner to establish a reference standard. Then, they were scanned five times with each intraoral scanner. The scans were compared using Geomagic Control X software to measure the root mean square (RMS) deviation. Statistical tests were conducted to assess and compare trueness and precision between and within groups.Results: For trueness, the One-Way ANOVA test showed no statistically significant differences among the three groups for anterior scan body, posterior scan body, and mucosal part (P-values: 0.14, 0.45, and 0.40 respectively). For precision, significant differences were found in the posterior scan body (P=0.03) and mucosal part (P=0.004), with the TRIOS 4 scanner demonstrating the highest precision. No significant differences between the three intraoral scanners were observed for the anterior scan body part (P=0.09).Conclusions: The study revealed that intraoral scanners exhibit varying precision for different anatomical regions, despite comparable trueness. This underscores the necessity of carefully considering scanner selection based on clinical requirements to guarantee accurate digital impressions and optimal treatment outcomes.

Authors

Institutions

Publication Details

Journal
Egyptian Dental Journal /Egyptian Dental Journal
Published
2025-01-01
DOI
https://doi.org/10.21608/edj.2024.329328.3236
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy of Digital Impressions Obtained by Different Intraoral Scanners Compared with The Laboratory Scanner for Implants Placed in Partially Edentulous Mandible: An In Vitro Study.

Amal Kaddah, Mohamed Farouk Abdallah, Nermeen Ahmed Hassan, Omar Sherif Abdelrahman
Egyptian Dental Journal /Egyptian Dental Journal
Dental Implant Techniques and Outcomes
article

Accuracy of Digital Impressions Obtained by Different Intraoral Scanners Compared with The Laboratory Scanner for Implants Placed in Partially Edentulous Mandible: An In Vitro Study.

Amal Kaddah, Mohamed Farouk Abdallah, Nermeen Ahmed Hassan, Omar Sherif Abdelrahman
article en

Abstract

Aim: The aim of this in vitro study was to evaluate the accuracy of three different intraoral scanners (Medit i700, 3Shape TRIOS 4 and Carestream CS3600) versus the desktop lab scanner for implants placed in Kennedy class II partially edentulous mandible.Methodology: A 3D-printed resin cast simulating a Kennedy Class II mandibular arch with two implants, in the first premolar and first molar regions, was used. Each scan body and the mucosal part of the edentulous area were scanned once by a laboratory scanner to establish a reference standard. Then, they were scanned five times with each intraoral scanner. The scans were compared using Geomagic Control X software to measure the root mean square (RMS) deviation. Statistical tests were conducted to assess and compare trueness and precision between and within groups.Results: For trueness, the One-Way ANOVA test showed no statistically significant differences among the three groups for anterior scan body, posterior scan body, and mucosal part (P-values: 0.14, 0.45, and 0.40 respectively). For precision, significant differences were found in the posterior scan body (P=0.03) and mucosal part (P=0.004), with the TRIOS 4 scanner demonstrating the highest precision. No significant differences between the three intraoral scanners were observed for the anterior scan body part (P=0.09).Conclusions: The study revealed that intraoral scanners exhibit varying precision for different anatomical regions, despite comparable trueness. This underscores the necessity of carefully considering scanner selection based on clinical requirements to guarantee accurate digital impressions and optimal treatment outcomes.

Egyptian Dental Journal /Egyptian Dental JournalVol. 71(1)
Cairo University (EG)
Openalex Percentile: Top 99%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.